1975•NASA STI Repository (National Aeronautics and Space Administration)Open access

Effect of wall suction on performance of a short annular diffuser at inlet Mach numbers up to 0.5

Albert J. Juhasz

Open full text 3 citations

Abstract

A short annular diffuser equipped with wall bleed (suction)capability was evaluated at inlet Mach numbers of 0.186 to 0.5. The diffuser had an area ratio of 4.0 and a length-to-inlet height ratio of 1.6. Test results show that the exit velocity profiles, typical of annular jet flow without suction, could be considerably flattened by application of wall suction. This improved performance was also reflected in diffuser effectiveness (static-pressure recovery) and total-pressure loss results. At the inlet Mach number of 0.5 diffuser static-pressure recovery is equal to or better than at lower inlet Mach numbers for comparable suction rates.

Open-access reader

About this research paper

What this paper is about

A short annular diffuser equipped with wall bleed (suction)capability was evaluated at inlet Mach numbers of 0.186 to 0.5. The diffuser had an area ratio of 4.0 and a length-to-inlet height ratio of 1.6. Test results show that the exit velocity profiles, typical of annular jet flow without suction, could be considerably flattened by application of wall suction. This improved performance was also reflected in diffuser effectiveness (static-pressure recovery) and total-pressure loss results. At the inlet Mach number of 0.5 diffuser static-pressure recovery is equal to or better than at lower inlet Mach numbers for comparable suction rates.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A short annular diffuser equipped with wall bleed (suction)capability was evaluated at inlet Mach numbers of 0.186 to 0.5. The diffuser had an area ratio of 4.0 and a length-to-inlet height ratio of 1.6. Test results show that the exit velocity profiles, typical of annular jet flow without suction, could be considerably flattened by application of wall suction. This improved performance was also reflected in diffuser effectiveness (static-pressure recovery) and total-pressure loss results. At the inlet Mach number of 0.5 diffuser static-pressure recovery is equal to or better than at lower inlet Mach numbers for comparable suction rates.

Key concepts: Diffuser (optics), Mach number, Suction, Inlet, Mechanics, Static pressure, Bleed, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of wall suction on performance of a short annular diffuser at inlet Mach numbers up to 0.5 — Research Paper | ScholarLens