Propofol Anaesthesia via Target Controlled Infusion or Manually Controlled Infusion: Effects on the Bispectral Index as a Measure of Anaesthetic Depth
Thomas C. E. Gale, Kate Leslie, Michal T. Kluger
Abstract
Thomas C. E. Gale, Kate Leslie, Michal T. Kluger
Abstract
Target controlled infusions (TCI) of propofol allow anaesthetists to target constant blood concentrations and respond promptly to signs of inappropriate anaesthetic depth. Studies comparing propofol TCI with manually controlled infusion (MCI) reported similar control of anaesthesia, but did not use an objective measure of anaesthetic depth. We therefore tested whether the Bispectral Index (BIS), an electroencephalographic (EEG) variable, is more stable during propofol TCI or MCI. Forty patients received midazolam and fentanyl before induction and were randomized to TCI or MCI. Target propofol concentrations in the TCI group were 3 to 8 microg/ml. The MCI group received propofol bolus (approximately 2 mg/kg) and infusion (3 to 10 mg/kg/h). Neuromuscular blockade was achieved with rocuronium. Following endotracheal intubation, nitrous oxide (66%) in oxygen was delivered and propofol infusion and fentanyl boluses were titrated against clinical signs. Blood pressure, heart rate and EEG were recorded, although the anaesthetist was blind to BIS values. The ideal BIS for general anaesthesia was defined as 50. Performance error, absolute performance error, wobble and divergence of BIS, and maximum changes in blood pressure and heart rate were compared using two-sample t-tests or rank-sum tests where appropriate. There was no difference in absolute performance errors during maintenance of anaesthesia with propofol TCI or MCI (23 +/- 11% vs 23 +/- 9%; P=0.97). The two groups did not differ significantly in performance error, wobble, divergence on haemodynamic changes. We conclude that TCI and MCI result in similar depth of anaesthesia and haemodynamic stability when titrated against traditional clinical signs.
OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Target controlled infusions (TCI) of propofol allow anaesthetists to target constant blood concentrations and respond promptly to signs of inappropriate anaesthetic depth. Studies comparing propofol TCI with manually controlled infusion (MCI) reported similar control of anaesthesia, but did not use an objective measure of anaesthetic depth. We therefore tested whether the Bispectral Index (BIS), an electroencephalographic (EEG) variable, is more stable during propofol TCI or MCI. Forty patients received midazolam and fentanyl before induction and were randomized to TCI or MCI. Target propofol concentrations in the TCI group were 3 to 8 microg/ml. The MCI group received propofol bolus (approximately 2 mg/kg) and infusion (3 to 10 mg/kg/h). Neuromuscular blockade was achieved with rocuronium. Following endotracheal intubation, nitrous oxide (66%) in oxygen was delivered and propofol infusion and fentanyl boluses were titrated against clinical signs. Blood pressure, heart rate and EEG were recorded, although the anaesthetist was blind to BIS values. The ideal BIS for general anaesthesia was defined as 50. Performance error, absolute performance error, wobble and divergence of BIS, and maximum changes in blood pressure and heart rate were compared using two-sample t-tests or rank-sum tests where appropriate. There was no difference in absolute performance errors during maintenance of anaesthesia with propofol TCI or MCI (23 +/- 11% vs 23 +/- 9%; P=0.97). The two groups did not differ significantly in performance error, wobble, divergence on haemodynamic changes. We conclude that TCI and MCI result in similar depth of anaesthesia and haemodynamic stability when titrated against traditional clinical signs.
Key concepts: Propofol, Medicine, Anesthesia, Bispectral index, Fentanyl, Rocuronium, Heart rate, Blood pressure