2024Results in EngineeringOpen access

Using froude and weber numbers to represent the changes in the flow pattern from stratified to stratified-wavy or plug for wire-on-tube condenser

Louay Abd Al-Azez Mahdi, Hasanain A. Abdul Wahhab, Miqdam T. Chaichan

Open full text 1 citations

Abstract

According to manufacturing data, a theoretical study of condensation inside a heat exchanger with wires on tubes. examined flow patterns with variable refrigerant mass flow rates . Wire-on-tube condensers are adopted with tubes, which have multiple diameters (3.25, 4.83 and 6.29 mm). In addition to the use of two refrigerants (R-134a, R-600a) working at condensing temperatures of (54.4, 45, and 35 °C). The Equal Equation Solver software (EES) was used to obtain the results for the mass velocity range from 8 to 167 kg s −1 m −2 . Using the non-dimensionless numbers, the model determines the refrigerant flow pattern. Weber number (We) and Froude number (Fr) were used for mass velocity in a range below 100 kg s −1 m −2 , which is recommended flow inside the wire-on-tube condenser. The initial transition of the two-phase flow pattern from stratified to stratified-wavy occurred at beginning of condensation for the quality range (0.78-0.42) was Fr (2.7-2.0) and We (6.1-4.0) for R-134a, while the quality range (0.85-0.39) was Fr (5.0-2.4) and We (7.0-4) for R-600a. Second, as the quality range approached, the stratified-wavy flow was replaced by a plug at quality (0.23-0.06) were Fr (1.5-0.4) and We (3.8-2.1) for R-134a and for R-600a the quality range (0.22-0.05) were Fr (1.7-0.55) and We (3.7-2.2).

About this research paper

What this paper is about

According to manufacturing data, a theoretical study of condensation inside a heat exchanger with wires on tubes. examined flow patterns with variable refrigerant mass flow rates . Wire-on-tube condensers are adopted with tubes, which have multiple diameters (3.25, 4.83 and 6.29 mm). In addition to the use of two refrigerants (R-134a, R-600a) working at condensing temperatures of (54.4, 45, and 35 °C). The Equal Equation Solver software (EES) was used to obtain the results for the mass velocity range from 8 to 167 kg s −1 m −2 . Using the non-dimensionless numbers, the model determines the refrigerant flow pattern. Weber number (We) and Froude number (Fr) were used for mass velocity in a range below 100 kg s −1 m −2 , which is recommended flow inside the wire-on-tube condenser. The initial transition of the two-phase flow pattern from stratified to stratified-wavy occurred at beginning of condensation for the quality range (0.78-0.42) was Fr (2.7-2.0) and We (6.1-4.0) for R-134a, while the quality range (0.85-0.39) was Fr (5.0-2.4) and We (7.0-4) for R-600a. Second, as the quality range approached, the stratified-wavy flow was replaced by a plug at quality (0.23-0.06) were Fr (1.5-0.4) and We (3.8-2.1) for R-134a and for R-600a the quality range (0.22-0.05) were Fr (1.7-0.55) and We (3.7-2.2).

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

According to manufacturing data, a theoretical study of condensation inside a heat exchanger with wires on tubes. examined flow patterns with variable refrigerant mass flow rates . Wire-on-tube condensers are adopted with tubes, which have multiple diameters (3.25, 4.83 and 6.29 mm). In addition to the use of two refrigerants (R-134a, R-600a) working at condensing temperatures of (54.4, 45, and 35 °C). The Equal Equation Solver software (EES) was used to obtain the results for the mass velocity range from 8 to 167 kg s −1 m −2 . Using the non-dimensionless numbers, the model determines the refrigerant flow pattern. Weber number (We) and Froude number (Fr) were used for mass velocity in a range below 100 kg s −1 m −2 , which is recommended flow inside the wire-on-tube condenser. The initial transition of the two-phase flow pattern from stratified to stratified-wavy occurred at beginning of condensation for the quality range (0.78-0.42) was Fr (2.7-2.0) and We (6.1-4.0) for R-134a, while the quality range (0.85-0.39) was Fr (5.0-2.4) and We (7.0-4) for R-600a. Second, as the quality range approached, the stratified-wavy flow was replaced by a plug at quality (0.23-0.06) were Fr (1.5-0.4) and We (3.8-2.1) for R-134a and for R-600a the quality range (0.22-0.05) were Fr (1.7-0.55) and We (3.7-2.2).

Key concepts: Froude number, Stratified flow, Stratified flows, Spark plug, Condenser (optics), Mechanics, Tube (container), Flow (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Using froude and weber numbers to represent the changes in the flow pattern from stratified to stratified-wavy or plug for wire-on-tube condenser — Research Paper | ScholarLens