A Review of Studies on Heat Transfer in Buildings with Radiant Cooling Systems
Rong Hu, Shilin Sun, Jincan Liang, Zhiping Zhou, Yingde Yin
Abstract
Open-access reader
Rong Hu, Shilin Sun, Jincan Liang, Zhiping Zhou, Yingde Yin
Abstract
Open-access reader
Due to their benefits in interior thermal comfort, energy saving, and noise reduction, radiant cooling systems have received wide attention. Radiant cooling systems can be viewed as a part of buildings’ maintenance structure and a component of cooling systems, depending on their construction. This article reviews studies on heat exchange in rooms utilizing radiant cooling systems, including research on conduction in radiant system structures, system cooling loads, cooling capacity, heat transfer coefficients of cooling surfaces, buildings’ thermal performance, and radiant system control strategy, with the goal of maximizing the benefits of energy conservation. Few studies have examined how radiant cooling systems interact with the indoor environment; instead, earlier research has focused on the thermal performance of radiant cooling systems themselves. Although several investigations have noted variations between the operating dynamics of radiant systems and conventional air conditioning systems, the cause has not yet been identified and quantified. According to heat transfer theory, the authors suggest that additional research on the performance of radiant systems should consider the thermal properties of inactive surfaces and that buildings’ thermal inertia should be used to coordinate radiant system operation.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Due to their benefits in interior thermal comfort, energy saving, and noise reduction, radiant cooling systems have received wide attention. Radiant cooling systems can be viewed as a part of buildings’ maintenance structure and a component of cooling systems, depending on their construction. This article reviews studies on heat exchange in rooms utilizing radiant cooling systems, including research on conduction in radiant system structures, system cooling loads, cooling capacity, heat transfer coefficients of cooling surfaces, buildings’ thermal performance, and radiant system control strategy, with the goal of maximizing the benefits of energy conservation. Few studies have examined how radiant cooling systems interact with the indoor environment; instead, earlier research has focused on the thermal performance of radiant cooling systems themselves. Although several investigations have noted variations between the operating dynamics of radiant systems and conventional air conditioning systems, the cause has not yet been identified and quantified. According to heat transfer theory, the authors suggest that additional research on the performance of radiant systems should consider the thermal properties of inactive surfaces and that buildings’ thermal inertia should be used to coordinate radiant system operation.
Key concepts: Radiant cooling, Radiant heating, Operative temperature, Radiant energy, Thermal comfort, Passive cooling, Heat transfer, Mean radiant temperature