DISCORDANCE BETWEEN HBA1C AND FASTING PLASMA GLUCOSE IN REACTIVE HYPOGLYCEMIA: A CASE SERIES
Mohan Varghese, Thomas Jacob Abraham, Jiby Mary John, Helen Elsa Manoj
Abstract
Mohan Varghese, Thomas Jacob Abraham, Jiby Mary John, Helen Elsa Manoj
Abstract
Background: Reactive Hypoglycemia (post prandial hypoglycemia) refers to recurrent episodes of low blood glucose levels that occur hours after a meal – usually within 2-5 hours after eating. It is considered to be a prediabetic state. We looked at the data of 15 patients Aims and Objectives: diagnosed with reactive hypoglycemia based on the evidence of Continuous Glucose Monitoring, to determine the correlation of reactive hypoglycemia with HbA1c and Fasting Plasma Glucose. In this series we obs Results: erved a discordance between HbA1c and Fasting Plasma Glucose in patients with Reactive Hypoglycemia. In addition, there was also a subset of patients that demonstrated normal HbA1c and Fasting Plasma Glucose. As it has been observed that patients with suspecte Conclusion: d Reactive Hypoglycemia show varied discordance between HbA1c and Fasting Plasma Glucose, it is recommended to use Continuous Glucose Monitoring in the evaluation of all patients with a suspicion of Reactive Hypoglycemia
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: Reactive Hypoglycemia (post prandial hypoglycemia) refers to recurrent episodes of low blood glucose levels that occur hours after a meal – usually within 2-5 hours after eating. It is considered to be a prediabetic state. We looked at the data of 15 patients Aims and Objectives: diagnosed with reactive hypoglycemia based on the evidence of Continuous Glucose Monitoring, to determine the correlation of reactive hypoglycemia with HbA1c and Fasting Plasma Glucose. In this series we obs Results: erved a discordance between HbA1c and Fasting Plasma Glucose in patients with Reactive Hypoglycemia. In addition, there was also a subset of patients that demonstrated normal HbA1c and Fasting Plasma Glucose. As it has been observed that patients with suspecte Conclusion: d Reactive Hypoglycemia show varied discordance between HbA1c and Fasting Plasma Glucose, it is recommended to use Continuous Glucose Monitoring in the evaluation of all patients with a suspicion of Reactive Hypoglycemia
Key concepts: Hypoglycemia, Plasma glucose, Medicine, Meal, Internal medicine, Endocrinology, Diabetes mellitus