2023AIP AdvancesOpen access

Triple Langmuir probe calibration in TOMAS ECRH plasma

J. Buermans, K. Crombé, L. Dittrich, A. Goriaev, Yu.V. Kovtun, D. López-Rodríguez, S. Möller, P. Petersson, M. Verstraeten

Open full text 5 citations

Abstract

In the TOMAS device, a triple Langmuir probe is used to measure the electron temperature and density. The accuracy of this measurement depends on correct determination of the effective collecting area of the probe, which depends on complex plasma transport processes. The probe can be calibrated by electron cyclotron resonance heating experiments using the cut-off density of the ordinary wave (O-wave). This threshold only depends on the frequency of the injected wave, and the occurrence of this phenomenon is clearly visible in the temperature evolution. The value of density is consequently known at this point and can be used to calibrate the density measurements of the triple Langmuir probe.

Open-access reader

About this research paper

What this paper is about

In the TOMAS device, a triple Langmuir probe is used to measure the electron temperature and density. The accuracy of this measurement depends on correct determination of the effective collecting area of the probe, which depends on complex plasma transport processes. The probe can be calibrated by electron cyclotron resonance heating experiments using the cut-off density of the ordinary wave (O-wave). This threshold only depends on the frequency of the injected wave, and the occurrence of this phenomenon is clearly visible in the temperature evolution. The value of density is consequently known at this point and can be used to calibrate the density measurements of the triple Langmuir probe.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the TOMAS device, a triple Langmuir probe is used to measure the electron temperature and density. The accuracy of this measurement depends on correct determination of the effective collecting area of the probe, which depends on complex plasma transport processes. The probe can be calibrated by electron cyclotron resonance heating experiments using the cut-off density of the ordinary wave (O-wave). This threshold only depends on the frequency of the injected wave, and the occurrence of this phenomenon is clearly visible in the temperature evolution. The value of density is consequently known at this point and can be used to calibrate the density measurements of the triple Langmuir probe.

Key concepts: Langmuir probe, Plasma diagnostics, Electron density, Plasma, Electron temperature, Atomic physics, Calibration, Plasma oscillation

Related papers

Back to paper searchBrowse research topicsOriginal source