First cannulation is a critical manoeuvre in equine laparoscopy. This retrospective study aimed at the comparison of the frequency and type of complications detected when using different human laparoscopy devices for laparoscopic access in standing horses, and the influence of body condition in such complications. Forty-four procedures were included, and retrieved data comprised cannula insertion technique, body condition, and type and frequency of complications. Laparoscopic access techniques were classified into five groups: P: pneumoperitoneum created using Veress needle prior to cannulation; T: sharp trocar; D: direct access via surgical incision; V: Visiport optical trocar and H: optical helical cannula (OHC). In groups T, D, V and H, access was achieved without prior induction of pneumoperitoneum. Complications were registered in 13/44 procedures, of which retroperitoneal insufflation was the most common (6/13). Statistically significant association was found between the complication incidence and the type of access, with group D showing the highest complication frequency (80%) and group H the lowest frequency (0%). The majority of complications (9/13) were observed in overweight horses. We conclude that devices designed for human patients can be used for laparoscopic access in standing horses, with the use of OHC minimizing the appearance of complications, especially in overweight horses with OW.

Open-access reader

About this research paper

What this paper is about

First cannulation is a critical manoeuvre in equine laparoscopy. This retrospective study aimed at the comparison of the frequency and type of complications detected when using different human laparoscopy devices for laparoscopic access in standing horses, and the influence of body condition in such complications. Forty-four procedures were included, and retrieved data comprised cannula insertion technique, body condition, and type and frequency of complications. Laparoscopic access techniques were classified into five groups: P: pneumoperitoneum created using Veress needle prior to cannulation; T: sharp trocar; D: direct access via surgical incision; V: Visiport optical trocar and H: optical helical cannula (OHC). In groups T, D, V and H, access was achieved without prior induction of pneumoperitoneum. Complications were registered in 13/44 procedures, of which retroperitoneal insufflation was the most common (6/13). Statistically significant association was found between the complication incidence and the type of access, with group D showing the highest complication frequency (80%) and group H the lowest frequency (0%). The majority of complications (9/13) were observed in overweight horses. We conclude that devices designed for human patients can be used for laparoscopic access in standing horses, with the use of OHC minimizing the appearance of complications, especially in overweight horses with OW.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

First cannulation is a critical manoeuvre in equine laparoscopy. This retrospective study aimed at the comparison of the frequency and type of complications detected when using different human laparoscopy devices for laparoscopic access in standing horses, and the influence of body condition in such complications. Forty-four procedures were included, and retrieved data comprised cannula insertion technique, body condition, and type and frequency of complications. Laparoscopic access techniques were classified into five groups: P: pneumoperitoneum created using Veress needle prior to cannulation; T: sharp trocar; D: direct access via surgical incision; V: Visiport optical trocar and H: optical helical cannula (OHC). In groups T, D, V and H, access was achieved without prior induction of pneumoperitoneum. Complications were registered in 13/44 procedures, of which retroperitoneal insufflation was the most common (6/13). Statistically significant association was found between the complication incidence and the type of access, with group D showing the highest complication frequency (80%) and group H the lowest frequency (0%). The majority of complications (9/13) were observed in overweight horses. We conclude that devices designed for human patients can be used for laparoscopic access in standing horses, with the use of OHC minimizing the appearance of complications, especially in overweight horses with OW.

Key concepts: Veress needle, Cannula, Medicine, Pneumoperitoneum, Insufflation, Laparoscopy, Surgery, Complication