2022•Pacing and Clinical ElectrophysiologyRequires access

Inappropriate ventricular fibrillation annotation and defibrillator discharge despite the same tachycardia cycle length in ventricular tachycardia‐1 zone in an Abbott defibrillator – What is the mechanism?

Debabrata Bera, Siddhartha Mani, Ranabrata Sen, Suchit Majumder, Antareep Halder, Adrita Ray

Open publisher page 2 citations

Abstract

Newer devices incorporate advanced algorithms to have more accurate delivery of implantable cardioverter-defibrillator (ICD) therapy. Newer models of Abbott Implantable cardioverter-defibrillators like Gallant and Entrant have a new ventricular fibrillation (VF) therapy assurance algorithm. This algorithm has a proven role in avoiding under-detection of VF where some of the smaller electrograms are under-sensed. We report a case of ventricular fibrillation therapy assurance (VFTA) algorithm malfunction in a 48-year-old lady having single chamber Entrant Implantable cardioverter-defibrillator, where the patient received inappropriate therapies. The VFTA algorithm eventually had to be turned off.

About this research paper

What this paper is about

Newer devices incorporate advanced algorithms to have more accurate delivery of implantable cardioverter-defibrillator (ICD) therapy. Newer models of Abbott Implantable cardioverter-defibrillators like Gallant and Entrant have a new ventricular fibrillation (VF) therapy assurance algorithm. This algorithm has a proven role in avoiding under-detection of VF where some of the smaller electrograms are under-sensed. We report a case of ventricular fibrillation therapy assurance (VFTA) algorithm malfunction in a 48-year-old lady having single chamber Entrant Implantable cardioverter-defibrillator, where the patient received inappropriate therapies. The VFTA algorithm eventually had to be turned off.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Newer devices incorporate advanced algorithms to have more accurate delivery of implantable cardioverter-defibrillator (ICD) therapy. Newer models of Abbott Implantable cardioverter-defibrillators like Gallant and Entrant have a new ventricular fibrillation (VF) therapy assurance algorithm. This algorithm has a proven role in avoiding under-detection of VF where some of the smaller electrograms are under-sensed. We report a case of ventricular fibrillation therapy assurance (VFTA) algorithm malfunction in a 48-year-old lady having single chamber Entrant Implantable cardioverter-defibrillator, where the patient received inappropriate therapies. The VFTA algorithm eventually had to be turned off.

Key concepts: Medicine, Implantable cardioverter-defibrillator, Ventricular tachycardia, Ventricular fibrillation, Cardiology, Internal medicine, Tachycardia

Related papers

Back to paper searchBrowse research topicsOriginal source
Inappropriate ventricular fibrillation annotation and defibrillator discharge despite the same tachycardia cycle length in ventricular tachycardia‐1 zone in an Abbott defibrillator – What is the mechanism? — Research Paper | ScholarLens