2006Unpublished venueRequires access

Analysis of ventricular arrhythmia episodes in patients at risk for ventricular fibrillation

Michele Triventi, Sergio Valsecchi, Maurizio Landolina, Maurizio Gasparini, Maurizio Lunati, F. Censi, G Calcagnini, P. Bartolini

Open publisher page 1 citations

Abstract

Implantable cardioverter defibrillators (ICD) are usually implanted in patients with malignant ventricular tachyarrhytmias. Aim of this study was to investigate the recurrence of minor ventricular arrhythmias to predict the occurrence of ventricular fibrillation episodes in patients with ICD. The study design was a retrospective analysis of 237 patients, whose ICD was programmed to deliver electrical therapy only for ventricular fibrillation (VF) but not for ventricular tachycardia (VT). We calculated the number, the mean duration and the mean ventricular cycle of the non-sustained ventricular tachyarrhythmias (NST) and of the sustained ventricular tachyarrhythmias (ST). We found that VF patients had a significant higher incidence of ventricular tachycardia compared to the no-VF patients.In addition, the mean VT episodes duration was higher in patients of the VF group than in patients free from ventricular fibrillation and the ventricular cycle length resulted to be significantly shorter in VF patients. 1.

About this research paper

What this paper is about

Implantable cardioverter defibrillators (ICD) are usually implanted in patients with malignant ventricular tachyarrhytmias. Aim of this study was to investigate the recurrence of minor ventricular arrhythmias to predict the occurrence of ventricular fibrillation episodes in patients with ICD. The study design was a retrospective analysis of 237 patients, whose ICD was programmed to deliver electrical therapy only for ventricular fibrillation (VF) but not for ventricular tachycardia (VT). We calculated the number, the mean duration and the mean ventricular cycle of the non-sustained ventricular tachyarrhythmias (NST) and of the sustained ventricular tachyarrhythmias (ST). We found that VF patients had a significant higher incidence of ventricular tachycardia compared to the no-VF patients.In addition, the mean VT episodes duration was higher in patients of the VF group than in patients free from ventricular fibrillation and the ventricular cycle length resulted to be significantly shorter in VF patients. 1.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Implantable cardioverter defibrillators (ICD) are usually implanted in patients with malignant ventricular tachyarrhytmias. Aim of this study was to investigate the recurrence of minor ventricular arrhythmias to predict the occurrence of ventricular fibrillation episodes in patients with ICD. The study design was a retrospective analysis of 237 patients, whose ICD was programmed to deliver electrical therapy only for ventricular fibrillation (VF) but not for ventricular tachycardia (VT). We calculated the number, the mean duration and the mean ventricular cycle of the non-sustained ventricular tachyarrhythmias (NST) and of the sustained ventricular tachyarrhythmias (ST). We found that VF patients had a significant higher incidence of ventricular tachycardia compared to the no-VF patients.In addition, the mean VT episodes duration was higher in patients of the VF group than in patients free from ventricular fibrillation and the ventricular cycle length resulted to be significantly shorter in VF patients. 1.

Key concepts: Ventricular fibrillation, Ventricular tachycardia, Cardiology, Medicine, Internal medicine, Fibrillation, Incidence (geometry), Implantable cardioverter-defibrillator

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of ventricular arrhythmia episodes in patients at risk for ventricular fibrillation — Research Paper | ScholarLens