Variations in the morphology of apical constriction affecting electronic readings: An in vitro investigation using 3D ‐printed tooth models
Ju-Hee Nam, Lucila Piasecki, Doun Kwak, Jung Hwa Hong, Il‐Young Jung, Sung Ho Park, Sin‐Yeon Cho
Abstract
Ju-Hee Nam, Lucila Piasecki, Doun Kwak, Jung Hwa Hong, Il‐Young Jung, Sung Ho Park, Sin‐Yeon Cho
Abstract
We investigated the interference of apical constriction position and diameter on the accuracy of electronic apex locators using 3D-printed tooth models. Single-rooted tooth models with the same length, canal taper and major foramen, but variation in apical constriction position or size, were designed and 3D-printed. A mounting model was custom-made for precise measurement of both marks (0.5 and APEX/0.0) of two electronic apex locators. The electronic measurements of both devices were correlated significantly to the major foramen rather than apical constriction. The mean measurements of the group with 0.45 mm in apical constriction width were significantly shorter than those of the other groups for both marks of the two devices (p < 0.05). The variations in apical constriction position and width negatively affected the precision of the 0.5 mark of the tested devices. The 0.0 or APEX mark was consistently located the major foramen.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We investigated the interference of apical constriction position and diameter on the accuracy of electronic apex locators using 3D-printed tooth models. Single-rooted tooth models with the same length, canal taper and major foramen, but variation in apical constriction position or size, were designed and 3D-printed. A mounting model was custom-made for precise measurement of both marks (0.5 and APEX/0.0) of two electronic apex locators. The electronic measurements of both devices were correlated significantly to the major foramen rather than apical constriction. The mean measurements of the group with 0.45 mm in apical constriction width were significantly shorter than those of the other groups for both marks of the two devices (p < 0.05). The variations in apical constriction position and width negatively affected the precision of the 0.5 mark of the tested devices. The 0.0 or APEX mark was consistently located the major foramen.
Key concepts: Apical constriction, Apical foramen, Constriction, Apex (geometry), Anatomy, Materials science, Foramen, Position (finance)