2010Australian Endodontic JournalRequires access

In vivo comparison of the accuracy of two electronic apex locators

Luiz Fernando Machado Silveira, Fernanda V. Petry, Josué Martos, João Batista César Neto

Open publisher page 12 citations

Abstract

The aim of this study was to analyse in vivo the accuracy of two apex locators, Root ZX and Novapex, to determine the position of the apical constriction. Twenty-three human single-rooted teeth to be extracted for periodontal reasons constituted the experiment. Endodontic access was obtained and the apical constriction was determined by one of the apex locators after initial crown-down preparation. When the electronic marker indicated that the tip of the endodontic file was at the apical constriction, the teeth were filled with composite and then surgically removed. The presence of the endodontic file tip at the apical constriction was evaluated stereomicroscopically (30×) and confirming radiographs were exposed. The accuracy of Root ZX and Novapex was 91.7% and 81.8% respectively. Within the limits of this study, the evaluated apex locators have a similar clinical performance for the apical constriction location.

About this research paper

What this paper is about

The aim of this study was to analyse in vivo the accuracy of two apex locators, Root ZX and Novapex, to determine the position of the apical constriction. Twenty-three human single-rooted teeth to be extracted for periodontal reasons constituted the experiment. Endodontic access was obtained and the apical constriction was determined by one of the apex locators after initial crown-down preparation. When the electronic marker indicated that the tip of the endodontic file was at the apical constriction, the teeth were filled with composite and then surgically removed. The presence of the endodontic file tip at the apical constriction was evaluated stereomicroscopically (30×) and confirming radiographs were exposed. The accuracy of Root ZX and Novapex was 91.7% and 81.8% respectively. Within the limits of this study, the evaluated apex locators have a similar clinical performance for the apical constriction location.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to analyse in vivo the accuracy of two apex locators, Root ZX and Novapex, to determine the position of the apical constriction. Twenty-three human single-rooted teeth to be extracted for periodontal reasons constituted the experiment. Endodontic access was obtained and the apical constriction was determined by one of the apex locators after initial crown-down preparation. When the electronic marker indicated that the tip of the endodontic file was at the apical constriction, the teeth were filled with composite and then surgically removed. The presence of the endodontic file tip at the apical constriction was evaluated stereomicroscopically (30×) and confirming radiographs were exposed. The accuracy of Root ZX and Novapex was 91.7% and 81.8% respectively. Within the limits of this study, the evaluated apex locators have a similar clinical performance for the apical constriction location.

Key concepts: Apical constriction, Apex (geometry), Constriction, Crown (dentistry), Dentistry, In vivo, Apicoectomy, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
In vivo comparison of the accuracy of two electronic apex locators — Research Paper | ScholarLens