2022SymmetryOpen access

Energy Dissipation Enhanced by Multiple Hinges in Bridge Piers with CFST Y-Shaped Fuses

Qunfeng Liu, Zhaoyang Guo, Xing Wu, Kaile Lu, Xiang Ren, Jialong Xiao

Open full text 2 citations

Abstract

Concrete-filled steel tubular Y-shaped (CFST-Y) piers are good candidates for meeting the structural and aesthetic requirements of bridges. By using the theoretical and nonlinear static (pushover) analyses, the seismic performances of three types of CFST-Y piers were evaluated at different seismic hazard levels. The theoretical formulas were first proposed to estimate the lateral stiffnesses for piers with different pier–deck connections. Then, the structural ductility with the development of plastic hinges in piers was investigated based on the pushover analyses. The results demonstrate that the structural dimensions, deck mass, shear limit, and stiffness of bearings can remarkably affect the formation of hinges and thereby lead to different energy dissipation patterns to achieve the expected performance in piers. The findings suggest an economic design strategy of piers, using CFST-Y members as energy dissipation fuses with multiple hinges, to achieve low-level seismic performance cost-effectively.

Open-access reader

About this research paper

What this paper is about

Concrete-filled steel tubular Y-shaped (CFST-Y) piers are good candidates for meeting the structural and aesthetic requirements of bridges. By using the theoretical and nonlinear static (pushover) analyses, the seismic performances of three types of CFST-Y piers were evaluated at different seismic hazard levels. The theoretical formulas were first proposed to estimate the lateral stiffnesses for piers with different pier–deck connections. Then, the structural ductility with the development of plastic hinges in piers was investigated based on the pushover analyses. The results demonstrate that the structural dimensions, deck mass, shear limit, and stiffness of bearings can remarkably affect the formation of hinges and thereby lead to different energy dissipation patterns to achieve the expected performance in piers. The findings suggest an economic design strategy of piers, using CFST-Y members as energy dissipation fuses with multiple hinges, to achieve low-level seismic performance cost-effectively.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Concrete-filled steel tubular Y-shaped (CFST-Y) piers are good candidates for meeting the structural and aesthetic requirements of bridges. By using the theoretical and nonlinear static (pushover) analyses, the seismic performances of three types of CFST-Y piers were evaluated at different seismic hazard levels. The theoretical formulas were first proposed to estimate the lateral stiffnesses for piers with different pier–deck connections. Then, the structural ductility with the development of plastic hinges in piers was investigated based on the pushover analyses. The results demonstrate that the structural dimensions, deck mass, shear limit, and stiffness of bearings can remarkably affect the formation of hinges and thereby lead to different energy dissipation patterns to achieve the expected performance in piers. The findings suggest an economic design strategy of piers, using CFST-Y members as energy dissipation fuses with multiple hinges, to achieve low-level seismic performance cost-effectively.

Key concepts: Hinge, Dissipation, Structural engineering, Pier, Deck, Plastic hinge, Stiffness, Nonlinear system

Related papers

Back to paper searchBrowse research topicsOriginal source
Energy Dissipation Enhanced by Multiple Hinges in Bridge Piers with CFST Y-Shaped Fuses — Research Paper | ScholarLens