2024Civil Engineering JournalOpen access

Effect of Steel Fiber on Plastic Hinge Length of Concrete Columns: Buckingham Theory Application

Tavio, Bambang Sabariman, Slamet Widodo

Open full text 0 citations

Abstract

The accuracy of designing the performance of concrete structures nowadays not only depends on the use of standard materials (cement, sand, and gravel) for certain concrete strengths but also on the accuracy of using additional materials for concrete, such as steel fiber. The use of steel fiber not only can improve the performance of concrete structures to behave in a ductile manner but can also form plastic hinges according to design purposes. The design of the axial load of Pa=0.121.Ag.f'c is based on the prediction of the column’s axial capacity. The columns were designed to behave in a flexural manner. As predicted, the lengths of the plastic hinges were found not too long. Controlling the length of plastic hinges in the design of structural concrete members is necessary to avoid excessive displacements. The control is mainly related to the prediction of the plastic hinge length. Thus, in this case, a plastic hinge length formula is required. In the study, the length of the plastic hinges of columns, which are confined with square stirrups and reinforced with steel fiber with Vf = 0%, 0.5%, 1%, 1.5%, and 2%, is proposed. This plastic hinge length formula is proposed after all column test specimens have met the displacement ductility requirement of mD>4, meaning that all test specimens are defined as very ductile. Doi: 10.28991/CEJ-2024-010-05-03 Full Text: PDF

About this research paper

What this paper is about

The accuracy of designing the performance of concrete structures nowadays not only depends on the use of standard materials (cement, sand, and gravel) for certain concrete strengths but also on the accuracy of using additional materials for concrete, such as steel fiber. The use of steel fiber not only can improve the performance of concrete structures to behave in a ductile manner but can also form plastic hinges according to design purposes. The design of the axial load of Pa=0.121.Ag.f'c is based on the prediction of the column’s axial capacity. The columns were designed to behave in a flexural manner. As predicted, the lengths of the plastic hinges were found not too long. Controlling the length of plastic hinges in the design of structural concrete members is necessary to avoid excessive displacements. The control is mainly related to the prediction of the plastic hinge length. Thus, in this case, a plastic hinge length formula is required. In the study, the length of the plastic hinges of columns, which are confined with square stirrups and reinforced with steel fiber with Vf = 0%, 0.5%, 1%, 1.5%, and 2%, is proposed. This plastic hinge length formula is proposed after all column test specimens have met the displacement ductility requirement of mD>4, meaning that all test specimens are defined as very ductile. Doi: 10.28991/CEJ-2024-010-05-03 Full Text: PDF

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The accuracy of designing the performance of concrete structures nowadays not only depends on the use of standard materials (cement, sand, and gravel) for certain concrete strengths but also on the accuracy of using additional materials for concrete, such as steel fiber. The use of steel fiber not only can improve the performance of concrete structures to behave in a ductile manner but can also form plastic hinges according to design purposes. The design of the axial load of Pa=0.121.Ag.f'c is based on the prediction of the column’s axial capacity. The columns were designed to behave in a flexural manner. As predicted, the lengths of the plastic hinges were found not too long. Controlling the length of plastic hinges in the design of structural concrete members is necessary to avoid excessive displacements. The control is mainly related to the prediction of the plastic hinge length. Thus, in this case, a plastic hinge length formula is required. In the study, the length of the plastic hinges of columns, which are confined with square stirrups and reinforced with steel fiber with Vf = 0%, 0.5%, 1%, 1.5%, and 2%, is proposed. This plastic hinge length formula is proposed after all column test specimens have met the displacement ductility requirement of mD>4, meaning that all test specimens are defined as very ductile. Doi: 10.28991/CEJ-2024-010-05-03 Full Text: PDF

Key concepts: Hinge, Plastic hinge, Ductility (Earth science), Structural engineering, Materials science, Fibre-reinforced plastic, Flexural strength, Column (typography)

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Steel Fiber on Plastic Hinge Length of Concrete Columns: Buckingham Theory Application — Research Paper | ScholarLens