2022•Journal of Cataract & Refractive SurgeryRequires access

Comparison of keratometry using SS-OCT and dual Scheimpflug-Placido imaging in postmyopic corneal refractive surgery eyes

Karima S. Khimani, Adriana Ordonez, Rahul T. Pandit

Open publisher page 2 citations

Abstract

PURPOSE: To compare simulated (SimK) and total (True-K) keratometry and corneal astigmatism values between the IOLMaster 700 (IOLM) and Galilei G4 (G4) devices in postmyopic laser refractive surgery eyes. SETTING: Methodist Eye Associates, Blanton Eye Institute, Houston Methodist Hospital, Houston, Texas. DESIGN: Retrospective cohort study. METHODS: A chart review was conducted on patients with prior myopic laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), undergoing phacoemulsification at a single institution from May 2019 through January 2022, who underwent imaging with both the IOLM and G4. Exclusion criteria were prior radial keratotomy, keratoectatic diseases, and inability to obtain a reliable image. Mean, flat, and steep SimK and True-K (TK from the IOLM and TCP IOL from the G4) values and astigmatism magnitude were compared. RESULTS: 50 eyes of 50 patients were included. The mean difference in SimK and True-K between devices (IOLM - G4) was -0.04 (95% CI -0.13 to 0.06; P > .05) diopters (D) and 1.14 (95% CI 1.02 to 1.25; P < .05) D, respectively. The IOLM measured steeper True-K values than the G4. There were no statistically significant differences between devices for all other SimK values, whereas for True-K there were significant differences in flat K and steep K ( P < .05), but not astigmatism magnitude. CONCLUSIONS: Despite an overall good correlation in postmyopic laser refractive surgery eyes in keratometry and astigmatism measurements, there is a significant difference in True-K, with the IOLM measuring steeper values by about 1.0 D compared with the G4, similar to prior studies on nonrefractive surgery eyes.

About this research paper

What this paper is about

PURPOSE: To compare simulated (SimK) and total (True-K) keratometry and corneal astigmatism values between the IOLMaster 700 (IOLM) and Galilei G4 (G4) devices in postmyopic laser refractive surgery eyes. SETTING: Methodist Eye Associates, Blanton Eye Institute, Houston Methodist Hospital, Houston, Texas. DESIGN: Retrospective cohort study. METHODS: A chart review was conducted on patients with prior myopic laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), undergoing phacoemulsification at a single institution from May 2019 through January 2022, who underwent imaging with both the IOLM and G4. Exclusion criteria were prior radial keratotomy, keratoectatic diseases, and inability to obtain a reliable image. Mean, flat, and steep SimK and True-K (TK from the IOLM and TCP IOL from the G4) values and astigmatism magnitude were compared. RESULTS: 50 eyes of 50 patients were included. The mean difference in SimK and True-K between devices (IOLM - G4) was -0.04 (95% CI -0.13 to 0.06; P > .05) diopters (D) and 1.14 (95% CI 1.02 to 1.25; P < .05) D, respectively. The IOLM measured steeper True-K values than the G4. There were no statistically significant differences between devices for all other SimK values, whereas for True-K there were significant differences in flat K and steep K ( P < .05), but not astigmatism magnitude. CONCLUSIONS: Despite an overall good correlation in postmyopic laser refractive surgery eyes in keratometry and astigmatism measurements, there is a significant difference in True-K, with the IOLM measuring steeper values by about 1.0 D compared with the G4, similar to prior studies on nonrefractive surgery eyes.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare simulated (SimK) and total (True-K) keratometry and corneal astigmatism values between the IOLMaster 700 (IOLM) and Galilei G4 (G4) devices in postmyopic laser refractive surgery eyes. SETTING: Methodist Eye Associates, Blanton Eye Institute, Houston Methodist Hospital, Houston, Texas. DESIGN: Retrospective cohort study. METHODS: A chart review was conducted on patients with prior myopic laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), undergoing phacoemulsification at a single institution from May 2019 through January 2022, who underwent imaging with both the IOLM and G4. Exclusion criteria were prior radial keratotomy, keratoectatic diseases, and inability to obtain a reliable image. Mean, flat, and steep SimK and True-K (TK from the IOLM and TCP IOL from the G4) values and astigmatism magnitude were compared. RESULTS: 50 eyes of 50 patients were included. The mean difference in SimK and True-K between devices (IOLM - G4) was -0.04 (95% CI -0.13 to 0.06; P > .05) diopters (D) and 1.14 (95% CI 1.02 to 1.25; P < .05) D, respectively. The IOLM measured steeper True-K values than the G4. There were no statistically significant differences between devices for all other SimK values, whereas for True-K there were significant differences in flat K and steep K ( P < .05), but not astigmatism magnitude. CONCLUSIONS: Despite an overall good correlation in postmyopic laser refractive surgery eyes in keratometry and astigmatism measurements, there is a significant difference in True-K, with the IOLM measuring steeper values by about 1.0 D compared with the G4, similar to prior studies on nonrefractive surgery eyes.

Key concepts: Keratometer, Ophthalmology, Photorefractive keratectomy, Dioptre, Medicine, Astigmatism, Refractive surgery, Keratomileusis

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of keratometry using SS-OCT and dual Scheimpflug-Placido imaging in postmyopic corneal refractive surgery eyes — Research Paper | ScholarLens