2022Journal of Chromatography AOpen access

A simple method for routine measurement of organosulfur compounds in complex liquid and gaseous matrices

Margo Elzinga, Julian Zamudio, Sean van Boven kaarsmaker, Tonke van de Pol, Johannes B.M. Klok, Annemiek ter Heijne

Open full text 4 citations

Abstract

The measurement of VOSCs in complex matrices is challenging due to their volatile and reactive nature. A straightforward method using headspace chromatography was developed for routine analyses of organosulfur compounds in a high saline liquid matrix with a pH of 8.4. Direct sample acidification with a 1M acetate buffer (pH 3.6) showed an increased response for methanethiol, ethanethiol, propanethiol, dimethyl sulfide, dimethyl disulfide and diethyl disulfide. A good quadratic fit (R2 <0.995) was obtained for each compound over a calibration range of 5 µM-S until 125 µM-S (µmol sulfur/L). Gas standards were measured using the same chromatographic conditions over a calibration range of 0.08 µM-S until 1.85 µM-S (R2 <0.999). Gas standards could also be used to calibrate the liquid phase with a response ratio of 105.2% for ET, 107% for DMS, 105.7% for PT, 108.9% for DMDS and 106% for DEDS. This alternative calibration strategy reduced the preparation time and does not rely on liquid standards, which were unstable over time. This method was used to determine Henry constants for the organosulfur compounds both in demineralized water and the high saline liquid matrix and to analyze samples from a bio electrochemical experiment that treated methanethiol. This new method allows for routine analysis of samples originating from natural gas desulfurization plants and can potentially also be used to analyze organosulfur compounds in other complex waste streams.

Open-access reader

About this research paper

What this paper is about

The measurement of VOSCs in complex matrices is challenging due to their volatile and reactive nature. A straightforward method using headspace chromatography was developed for routine analyses of organosulfur compounds in a high saline liquid matrix with a pH of 8.4. Direct sample acidification with a 1M acetate buffer (pH 3.6) showed an increased response for methanethiol, ethanethiol, propanethiol, dimethyl sulfide, dimethyl disulfide and diethyl disulfide. A good quadratic fit (R2 <0.995) was obtained for each compound over a calibration range of 5 µM-S until 125 µM-S (µmol sulfur/L). Gas standards were measured using the same chromatographic conditions over a calibration range of 0.08 µM-S until 1.85 µM-S (R2 <0.999). Gas standards could also be used to calibrate the liquid phase with a response ratio of 105.2% for ET, 107% for DMS, 105.7% for PT, 108.9% for DMDS and 106% for DEDS. This alternative calibration strategy reduced the preparation time and does not rely on liquid standards, which were unstable over time. This method was used to determine Henry constants for the organosulfur compounds both in demineralized water and the high saline liquid matrix and to analyze samples from a bio electrochemical experiment that treated methanethiol. This new method allows for routine analysis of samples originating from natural gas desulfurization plants and can potentially also be used to analyze organosulfur compounds in other complex waste streams.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The measurement of VOSCs in complex matrices is challenging due to their volatile and reactive nature. A straightforward method using headspace chromatography was developed for routine analyses of organosulfur compounds in a high saline liquid matrix with a pH of 8.4. Direct sample acidification with a 1M acetate buffer (pH 3.6) showed an increased response for methanethiol, ethanethiol, propanethiol, dimethyl sulfide, dimethyl disulfide and diethyl disulfide. A good quadratic fit (R2 <0.995) was obtained for each compound over a calibration range of 5 µM-S until 125 µM-S (µmol sulfur/L). Gas standards were measured using the same chromatographic conditions over a calibration range of 0.08 µM-S until 1.85 µM-S (R2 <0.999). Gas standards could also be used to calibrate the liquid phase with a response ratio of 105.2% for ET, 107% for DMS, 105.7% for PT, 108.9% for DMDS and 106% for DEDS. This alternative calibration strategy reduced the preparation time and does not rely on liquid standards, which were unstable over time. This method was used to determine Henry constants for the organosulfur compounds both in demineralized water and the high saline liquid matrix and to analyze samples from a bio electrochemical experiment that treated methanethiol. This new method allows for routine analysis of samples originating from natural gas desulfurization plants and can potentially also be used to analyze organosulfur compounds in other complex waste streams.

Key concepts: Organosulfur compounds, Methanethiol, Chemistry, Ethanethiol, Sulfur, Gas chromatography, Dimethyl disulfide, Derivatization

Related papers

Back to paper searchBrowse research topicsOriginal source
A simple method for routine measurement of organosulfur compounds in complex liquid and gaseous matrices — Research Paper | ScholarLens