1914Proceedings of the American Institute of Electrical EngineersRequires access

Outdoor substations in New England

Fred L. Hunt

Open publisher page 0 citations

Abstract

The present development of outdoor switching apparatus and transformers for systems of 110,000 volts or less is such as to make their use entirely successful, and in most transformer substations, a considerable saving in first cost can be accomplished without increase in operating expenses, by making use of this type of equipment. This paper gives a brief description of two substations of 10,000 kv-a. ultimate capacity, just put into operation, in which all the high-tension switching apparatus (66,000 volts) and the transformers are outdoors. The low-tension apparatus (13,200 volts) and the railway apparatus are indoors. This arrangement is based on the three following principles which have in this case proved to be sound: 1. That the greatest saving in building cost can be made by putting all high-tension work outdoors. 2. That the switching apparatus, lightning arresters and transformers of voltages in the neighborhood of 66,000 volts are practical and may be successfully operated outdoors in New England. 3. That distributing switchboard, control switchboard and railway apparatus and switchboard are not suitable for outdoors.

About this research paper

What this paper is about

The present development of outdoor switching apparatus and transformers for systems of 110,000 volts or less is such as to make their use entirely successful, and in most transformer substations, a considerable saving in first cost can be accomplished without increase in operating expenses, by making use of this type of equipment. This paper gives a brief description of two substations of 10,000 kv-a. ultimate capacity, just put into operation, in which all the high-tension switching apparatus (66,000 volts) and the transformers are outdoors. The low-tension apparatus (13,200 volts) and the railway apparatus are indoors. This arrangement is based on the three following principles which have in this case proved to be sound: 1. That the greatest saving in building cost can be made by putting all high-tension work outdoors. 2. That the switching apparatus, lightning arresters and transformers of voltages in the neighborhood of 66,000 volts are practical and may be successfully operated outdoors in New England. 3. That distributing switchboard, control switchboard and railway apparatus and switchboard are not suitable for outdoors.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The present development of outdoor switching apparatus and transformers for systems of 110,000 volts or less is such as to make their use entirely successful, and in most transformer substations, a considerable saving in first cost can be accomplished without increase in operating expenses, by making use of this type of equipment. This paper gives a brief description of two substations of 10,000 kv-a. ultimate capacity, just put into operation, in which all the high-tension switching apparatus (66,000 volts) and the transformers are outdoors. The low-tension apparatus (13,200 volts) and the railway apparatus are indoors. This arrangement is based on the three following principles which have in this case proved to be sound: 1. That the greatest saving in building cost can be made by putting all high-tension work outdoors. 2. That the switching apparatus, lightning arresters and transformers of voltages in the neighborhood of 66,000 volts are practical and may be successfully operated outdoors in New England. 3. That distributing switchboard, control switchboard and railway apparatus and switchboard are not suitable for outdoors.

Key concepts: Volt, Transformer, Electrical engineering, Engineering, Voltage, High tension, High voltage, Automotive engineering