2017Asian Education StudiesOpen access

Power Transformer Wire Estimate

Angelo B. Dalaguit, Mary Ann L. Dalaguit

Open full text 0 citations

Abstract

This experimental study determined the weight of wire used in power supply using the laboratory technique and procedure to gather data. There were two designs with three treatments each, prepared and subjected to using the Two Way Analysis of Variance. The treatments for the first design were: one is 1 1/8 inch by 1 1/8 inch area and output voltage of 6 volts; two is 1 1/8 inch by 1 1/8 inch area and output voltage of 36 volts; three is 1 1/8 inch by 1 1/8 inch area and output voltage of 110 volts. The treatments for design number two were: one is 1/2 inch by 1/2 inch area and output voltage of 12 volts; two is 3/4 inch by 3/4 inch area and output voltage of 12 volts; three is 1 inch by 1 inch area and output voltage of 12 volts. The test result of significant differences in the effectiveness, efficiency and performance of the different treatments showed no significant difference on windings, temperature, voltage, size of the iron core, current, power, number of turns, turns per volt and force applied in winding.

Open-access reader

About this research paper

What this paper is about

This experimental study determined the weight of wire used in power supply using the laboratory technique and procedure to gather data. There were two designs with three treatments each, prepared and subjected to using the Two Way Analysis of Variance. The treatments for the first design were: one is 1 1/8 inch by 1 1/8 inch area and output voltage of 6 volts; two is 1 1/8 inch by 1 1/8 inch area and output voltage of 36 volts; three is 1 1/8 inch by 1 1/8 inch area and output voltage of 110 volts. The treatments for design number two were: one is 1/2 inch by 1/2 inch area and output voltage of 12 volts; two is 3/4 inch by 3/4 inch area and output voltage of 12 volts; three is 1 inch by 1 inch area and output voltage of 12 volts. The test result of significant differences in the effectiveness, efficiency and performance of the different treatments showed no significant difference on windings, temperature, voltage, size of the iron core, current, power, number of turns, turns per volt and force applied in winding.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This experimental study determined the weight of wire used in power supply using the laboratory technique and procedure to gather data. There were two designs with three treatments each, prepared and subjected to using the Two Way Analysis of Variance. The treatments for the first design were: one is 1 1/8 inch by 1 1/8 inch area and output voltage of 6 volts; two is 1 1/8 inch by 1 1/8 inch area and output voltage of 36 volts; three is 1 1/8 inch by 1 1/8 inch area and output voltage of 110 volts. The treatments for design number two were: one is 1/2 inch by 1/2 inch area and output voltage of 12 volts; two is 3/4 inch by 3/4 inch area and output voltage of 12 volts; three is 1 inch by 1 inch area and output voltage of 12 volts. The test result of significant differences in the effectiveness, efficiency and performance of the different treatments showed no significant difference on windings, temperature, voltage, size of the iron core, current, power, number of turns, turns per volt and force applied in winding.

Key concepts: Volt, Voltage, Electrical engineering, Transformer, Power (physics), Electromagnetic coil, Materials science, Engineering