2006Dermatologic SurgeryRequires access

Prospective, Randomized, Blinded Study of a New Wound Closure Film Versus Cutaneous Suture for Surgical Wound Closure

Felix Kuo, DENNIS LEE, Gary S. Rogers

Open publisher page 4 citations

Abstract

BACKGROUND Wound closure devices include sutures, tissue adhesives, adhesive strips, and staples. Recent studies suggest no differences between various tissue adhesives and sutures for dehiscence, infection, and satisfaction when assessed by patients or surgeons. To date, no studies have investigated ClozeX (Clozex Medical LLC, Wellesley, MA, USA), a novel adhesive strip, for closure of surgical incisions. OBJECTIVE To compare surgical wounds repaired with ClozeX versus suture. METHODS A prospective, randomized study was conducted, in which 15 patients with surgical incisions were allocated to closure with ClozeX on half of the wound and monofilament suture on the other half. Physician satisfaction with blinded assessment, patient satisfaction, complication rates, and closure times were recorded. RESULTS Application with ClozeX was faster than with suture (p=.007). There were no complications in either group. Sixty-nine percent of the patients gave ClozeX a higher satisfaction score (p=.02). More physicians were satisfied with the ClozeX half than with the suture half (p=.007). CONCLUSIONS This pilot study demonstrates ClozeX to be a safe and effective closure device. The cosmetic outcome seems to be at least as good as simple running suture. Physicians and patients were generally more satisfied with ClozeX. No difference was found in the rate of dehiscence or infection between the groups.

About this research paper

What this paper is about

BACKGROUND Wound closure devices include sutures, tissue adhesives, adhesive strips, and staples. Recent studies suggest no differences between various tissue adhesives and sutures for dehiscence, infection, and satisfaction when assessed by patients or surgeons. To date, no studies have investigated ClozeX (Clozex Medical LLC, Wellesley, MA, USA), a novel adhesive strip, for closure of surgical incisions. OBJECTIVE To compare surgical wounds repaired with ClozeX versus suture. METHODS A prospective, randomized study was conducted, in which 15 patients with surgical incisions were allocated to closure with ClozeX on half of the wound and monofilament suture on the other half. Physician satisfaction with blinded assessment, patient satisfaction, complication rates, and closure times were recorded. RESULTS Application with ClozeX was faster than with suture (p=.007). There were no complications in either group. Sixty-nine percent of the patients gave ClozeX a higher satisfaction score (p=.02). More physicians were satisfied with the ClozeX half than with the suture half (p=.007). CONCLUSIONS This pilot study demonstrates ClozeX to be a safe and effective closure device. The cosmetic outcome seems to be at least as good as simple running suture. Physicians and patients were generally more satisfied with ClozeX. No difference was found in the rate of dehiscence or infection between the groups.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND Wound closure devices include sutures, tissue adhesives, adhesive strips, and staples. Recent studies suggest no differences between various tissue adhesives and sutures for dehiscence, infection, and satisfaction when assessed by patients or surgeons. To date, no studies have investigated ClozeX (Clozex Medical LLC, Wellesley, MA, USA), a novel adhesive strip, for closure of surgical incisions. OBJECTIVE To compare surgical wounds repaired with ClozeX versus suture. METHODS A prospective, randomized study was conducted, in which 15 patients with surgical incisions were allocated to closure with ClozeX on half of the wound and monofilament suture on the other half. Physician satisfaction with blinded assessment, patient satisfaction, complication rates, and closure times were recorded. RESULTS Application with ClozeX was faster than with suture (p=.007). There were no complications in either group. Sixty-nine percent of the patients gave ClozeX a higher satisfaction score (p=.02). More physicians were satisfied with the ClozeX half than with the suture half (p=.007). CONCLUSIONS This pilot study demonstrates ClozeX to be a safe and effective closure device. The cosmetic outcome seems to be at least as good as simple running suture. Physicians and patients were generally more satisfied with ClozeX. No difference was found in the rate of dehiscence or infection between the groups.

Key concepts: Medicine, Surgery, Fibrous joint, Dehiscence, Patient satisfaction, Wound closure, Wound dehiscence, Prospective cohort study

Related papers

Back to paper searchBrowse research topicsOriginal source
Prospective, Randomized, Blinded Study of a New Wound Closure Film Versus Cutaneous Suture for Surgical Wound Closure — Research Paper | ScholarLens