1998Anesthesia & AnalgesiaRequires access

Pneumoperitoneum as a Risk Factor for Endobronchial Intubation During Laparoscopic Gynecologic Surgery

Emilio B. Lobato, Glenn B. Paige, Michelle M. Brown, Barbara B. Bennett, John D. Davis

Open publisher page 7 citations

Abstract

Patients undergoing gynecological surgery under laparoscopic guidance usually receive general anesthesia with endotracheal intubation and mechanical ventilation.The creation of a pneumoperitoneum and the Trendelenburg position, both of which are used to improve visualization, are associated with cephalad movement of the diaphragm. This may increase the risk of endobronchial intubation. We studied the change in the distance from the tip of the endotracheal tube (ETT) to the carina with a fiberoptic bronchoscope in 30 patients aged 21-40 yr who were undergoing laparoscopic tubal ligation (n = 28) or hysterectomy (n = 2). Measurements were taken in the supine and Trendelenburg positions before and after pneumoperitoneum. The average distance from the ETT to the carina in the supine position was 2.1 +/- 0.8 cm and in the Trendelenburg position was 1.8 +/- 0.8 cm (P = not significant). After insufflation of the abdominal cavity, the mean distance decreased to 0.7 +/- 1.4 cm in the supine position (P < 0.05) and was associated with endobronchial intubation in eight patients. The addition of the Trendelenburg position to an established pneumoperitoneum resulted in minimal displacement (0.54 +/- 1.4 cm, P < 0.05) and one additional endobronchial intubation. We conclude that the insufflation of gas in the abdominal cavity, and not the change in patient position, is the main risk factor for endobronchial intubation in patients undergoing laparoscopic gynecologic surgery. Implications: This study demonstrated that in anesthetized women, the insufflation of gas into the abdomen during laparoscopy for gynecologic surgery is the main risk factor for migration of the endotracheal tube into a bronchus. (Anesth Analg 1998;86:301-3)

About this research paper

What this paper is about

Patients undergoing gynecological surgery under laparoscopic guidance usually receive general anesthesia with endotracheal intubation and mechanical ventilation.The creation of a pneumoperitoneum and the Trendelenburg position, both of which are used to improve visualization, are associated with cephalad movement of the diaphragm. This may increase the risk of endobronchial intubation. We studied the change in the distance from the tip of the endotracheal tube (ETT) to the carina with a fiberoptic bronchoscope in 30 patients aged 21-40 yr who were undergoing laparoscopic tubal ligation (n = 28) or hysterectomy (n = 2). Measurements were taken in the supine and Trendelenburg positions before and after pneumoperitoneum. The average distance from the ETT to the carina in the supine position was 2.1 +/- 0.8 cm and in the Trendelenburg position was 1.8 +/- 0.8 cm (P = not significant). After insufflation of the abdominal cavity, the mean distance decreased to 0.7 +/- 1.4 cm in the supine position (P < 0.05) and was associated with endobronchial intubation in eight patients. The addition of the Trendelenburg position to an established pneumoperitoneum resulted in minimal displacement (0.54 +/- 1.4 cm, P < 0.05) and one additional endobronchial intubation. We conclude that the insufflation of gas in the abdominal cavity, and not the change in patient position, is the main risk factor for endobronchial intubation in patients undergoing laparoscopic gynecologic surgery. Implications: This study demonstrated that in anesthetized women, the insufflation of gas into the abdomen during laparoscopy for gynecologic surgery is the main risk factor for migration of the endotracheal tube into a bronchus. (Anesth Analg 1998;86:301-3)

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Patients undergoing gynecological surgery under laparoscopic guidance usually receive general anesthesia with endotracheal intubation and mechanical ventilation.The creation of a pneumoperitoneum and the Trendelenburg position, both of which are used to improve visualization, are associated with cephalad movement of the diaphragm. This may increase the risk of endobronchial intubation. We studied the change in the distance from the tip of the endotracheal tube (ETT) to the carina with a fiberoptic bronchoscope in 30 patients aged 21-40 yr who were undergoing laparoscopic tubal ligation (n = 28) or hysterectomy (n = 2). Measurements were taken in the supine and Trendelenburg positions before and after pneumoperitoneum. The average distance from the ETT to the carina in the supine position was 2.1 +/- 0.8 cm and in the Trendelenburg position was 1.8 +/- 0.8 cm (P = not significant). After insufflation of the abdominal cavity, the mean distance decreased to 0.7 +/- 1.4 cm in the supine position (P < 0.05) and was associated with endobronchial intubation in eight patients. The addition of the Trendelenburg position to an established pneumoperitoneum resulted in minimal displacement (0.54 +/- 1.4 cm, P < 0.05) and one additional endobronchial intubation. We conclude that the insufflation of gas in the abdominal cavity, and not the change in patient position, is the main risk factor for endobronchial intubation in patients undergoing laparoscopic gynecologic surgery. Implications: This study demonstrated that in anesthetized women, the insufflation of gas into the abdomen during laparoscopy for gynecologic surgery is the main risk factor for migration of the endotracheal tube into a bronchus. (Anesth Analg 1998;86:301-3)

Key concepts: Medicine, Pneumoperitoneum, Trendelenburg, Trendelenburg position, Insufflation, Supine position, Intubation, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Pneumoperitoneum as a Risk Factor for Endobronchial Intubation During Laparoscopic Gynecologic Surgery — Research Paper | ScholarLens