2010PubMedOpen access

Tube migration during laparoscopic gynecological surgery.

Nishkarsh Gupta, Kiran Girdhar, Anil Misra, Raktima Anand, Akhil Kumar, Gunjan

Open full text 9 citations

Abstract

BACKGROUND: The positioning (trendelenburg) and pneumoperitoneum during laparoscopic gynecological surgeries may cause cephalad movement of diaphragm and subsequent endobronchial intubation. PATIENTS #ENTITYSTARTX00026; METHODS: 50 ASA I/II patients posted for laparoscopic ligation were included in the study. Standardized anaesthesia technique was employed in all the patients. The distance of endotracheal tube to carina was measured in supine position, trendelenberg position, 5 min and 25 minutes post pneumoperitoneum and after deflation of pneumo-peritoneum. RESULTS: The mean distance from the tip of the ETT to the carina was 3.41± 1.3 cm, 2.96 ± 1.4, 2.0 ± 1.5 and 1.7 ± 1.6 in supine position, trendelenburg position and 5min and 25 min post pneumoperitoneum. (P<0.01) Following deflation the carina moved back to its position to some extent and was 2.5 ± 1.5 from the tip of endotracheal tube.( P< 0.05) CONCLUSION: We conclude that pneumoperitoneum and trendelenburg position during laparoscopic surgeries may lead to cephalad migration of carina.

About this research paper

What this paper is about

BACKGROUND: The positioning (trendelenburg) and pneumoperitoneum during laparoscopic gynecological surgeries may cause cephalad movement of diaphragm and subsequent endobronchial intubation. PATIENTS #ENTITYSTARTX00026; METHODS: 50 ASA I/II patients posted for laparoscopic ligation were included in the study. Standardized anaesthesia technique was employed in all the patients. The distance of endotracheal tube to carina was measured in supine position, trendelenberg position, 5 min and 25 minutes post pneumoperitoneum and after deflation of pneumo-peritoneum. RESULTS: The mean distance from the tip of the ETT to the carina was 3.41± 1.3 cm, 2.96 ± 1.4, 2.0 ± 1.5 and 1.7 ± 1.6 in supine position, trendelenburg position and 5min and 25 min post pneumoperitoneum. (P<0.01) Following deflation the carina moved back to its position to some extent and was 2.5 ± 1.5 from the tip of endotracheal tube.( P< 0.05) CONCLUSION: We conclude that pneumoperitoneum and trendelenburg position during laparoscopic surgeries may lead to cephalad migration of carina.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The positioning (trendelenburg) and pneumoperitoneum during laparoscopic gynecological surgeries may cause cephalad movement of diaphragm and subsequent endobronchial intubation. PATIENTS #ENTITYSTARTX00026; METHODS: 50 ASA I/II patients posted for laparoscopic ligation were included in the study. Standardized anaesthesia technique was employed in all the patients. The distance of endotracheal tube to carina was measured in supine position, trendelenberg position, 5 min and 25 minutes post pneumoperitoneum and after deflation of pneumo-peritoneum. RESULTS: The mean distance from the tip of the ETT to the carina was 3.41± 1.3 cm, 2.96 ± 1.4, 2.0 ± 1.5 and 1.7 ± 1.6 in supine position, trendelenburg position and 5min and 25 min post pneumoperitoneum. (P<0.01) Following deflation the carina moved back to its position to some extent and was 2.5 ± 1.5 from the tip of endotracheal tube.( P< 0.05) CONCLUSION: We conclude that pneumoperitoneum and trendelenburg position during laparoscopic surgeries may lead to cephalad migration of carina.

Key concepts: Pneumoperitoneum, Medicine, Trendelenburg position, Trendelenburg, Supine position, Laparoscopic surgery, Intubation, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source