2022•ElectroanalysisRequires access

Simultaneous Determination of Gallic Acid and Folic Acid in Fruit Juice Samples Using Square Wave Voltammetry at Electrochemically Pretreated Carbon Paste Electrode

Gizaw Tesfaye, Negussie Negash, Tesfu Hailu, Merid Tessema

Open publisher page 7 citations

Abstract

Abstract An efficient sensor was developed for the simultaneous determination of gallic and folic acid in juice samples using an electrochemically pretreated carbon paste electrode. The electrode was characterized by CV and EIS. The electrochemical behavior of GA and FA was evaluated by CV and SWV. The electrode exhibited high electrocatalytic activity towards GA and FA due to high surface area. Under the optimized condition, linear plots in the ranges of 0.08–13 μM and 0.1 to 15 μM were obtained for GA and FA, respectively. The proposed method was successful for the simultaneous determination of GA and FA in juice samples with satisfactory recovery.

About this research paper

What this paper is about

Abstract An efficient sensor was developed for the simultaneous determination of gallic and folic acid in juice samples using an electrochemically pretreated carbon paste electrode. The electrode was characterized by CV and EIS. The electrochemical behavior of GA and FA was evaluated by CV and SWV. The electrode exhibited high electrocatalytic activity towards GA and FA due to high surface area. Under the optimized condition, linear plots in the ranges of 0.08–13 μM and 0.1 to 15 μM were obtained for GA and FA, respectively. The proposed method was successful for the simultaneous determination of GA and FA in juice samples with satisfactory recovery.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract An efficient sensor was developed for the simultaneous determination of gallic and folic acid in juice samples using an electrochemically pretreated carbon paste electrode. The electrode was characterized by CV and EIS. The electrochemical behavior of GA and FA was evaluated by CV and SWV. The electrode exhibited high electrocatalytic activity towards GA and FA due to high surface area. Under the optimized condition, linear plots in the ranges of 0.08–13 μM and 0.1 to 15 μM were obtained for GA and FA, respectively. The proposed method was successful for the simultaneous determination of GA and FA in juice samples with satisfactory recovery.

Key concepts: Gallic acid, Carbon paste electrode, Square wave, Electrode, Folic acid, Chemistry, Electrochemistry, Voltammetry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Gallic Acid and Folic Acid in Fruit Juice Samples Using Square Wave Voltammetry at Electrochemically Pretreated Carbon Paste Electrode — Research Paper | ScholarLens