This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power. The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool. Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building. LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool. A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case. So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case. The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration. ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode. KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case. Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases. The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.

Open-access reader

About this research paper

What this paper is about

This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power. The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool. Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building. LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool. A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case. So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case. The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration. ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode. KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case. Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases. The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power. The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool. Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building. LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool. A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case. So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case. The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration. ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode. KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case. Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases. The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.

Key concepts: Shutdown, Nuclear engineering, Nuclear reactor core, Loss-of-coolant accident, Environmental science, Coolant, Research reactor, Reactor pressure vessel