2021International Journal of Advanced Nursing StudiesOpen access

Factors associated with hemodialysis adequacy among end stage renal disease patients on maintenance hemodialysis in Rwanda

Didace Ndahayo, Emmanuel Bimenyimana Gapira, Theos Mbabazi, Geldine Chironda

Open full text 7 citations

Abstract

The aim of this study was to assess the factors associated with dialysis adequacy in ESRD patients on maintenance hemodialysis in Rwanda. A descriptive cross-sectional study was conducted. A sample size of 66 hemodialysis patients was selected using purposive sampling strategy. An interview scheduled guide was used to collect data. Dialysis adequacy was calculated using kt/v Daugirdas & Schneditz formula. The mean hemodialysis adequacy was 1.26± 0.34. Most participants [41(62%)] had optimal hemodialysis adequacy of equal or greater than to 1.2, 19 (29%) had near optimal hemodialysis adequacy (0.8 - 1.2 kt/v) and only 6 (9%) had less than optimal hemodialysis adequacy (kt/v <0.8). Factors associated with hemodialysis adequacy were hospital settings (p = .010), age (p = .007), BMI (p =.004) and blood pressure level ((p = .018). Moreover, mode of transport and type of drinking water was significantly associated with hemodialysis adequacy (p = 0.032 and 0.030 respectively). In conclusion, the level of hemodialysis adequacy was low in 38% of ESRD patients with associated factors predominantly demographics. Therefore, further research inquiry is needed on additional factors which include technical aspects to establish their association with hemodialysis adequacy.

Open-access reader

About this research paper

What this paper is about

The aim of this study was to assess the factors associated with dialysis adequacy in ESRD patients on maintenance hemodialysis in Rwanda. A descriptive cross-sectional study was conducted. A sample size of 66 hemodialysis patients was selected using purposive sampling strategy. An interview scheduled guide was used to collect data. Dialysis adequacy was calculated using kt/v Daugirdas & Schneditz formula. The mean hemodialysis adequacy was 1.26± 0.34. Most participants [41(62%)] had optimal hemodialysis adequacy of equal or greater than to 1.2, 19 (29%) had near optimal hemodialysis adequacy (0.8 - 1.2 kt/v) and only 6 (9%) had less than optimal hemodialysis adequacy (kt/v <0.8). Factors associated with hemodialysis adequacy were hospital settings (p = .010), age (p = .007), BMI (p =.004) and blood pressure level ((p = .018). Moreover, mode of transport and type of drinking water was significantly associated with hemodialysis adequacy (p = 0.032 and 0.030 respectively). In conclusion, the level of hemodialysis adequacy was low in 38% of ESRD patients with associated factors predominantly demographics. Therefore, further research inquiry is needed on additional factors which include technical aspects to establish their association with hemodialysis adequacy.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to assess the factors associated with dialysis adequacy in ESRD patients on maintenance hemodialysis in Rwanda. A descriptive cross-sectional study was conducted. A sample size of 66 hemodialysis patients was selected using purposive sampling strategy. An interview scheduled guide was used to collect data. Dialysis adequacy was calculated using kt/v Daugirdas & Schneditz formula. The mean hemodialysis adequacy was 1.26± 0.34. Most participants [41(62%)] had optimal hemodialysis adequacy of equal or greater than to 1.2, 19 (29%) had near optimal hemodialysis adequacy (0.8 - 1.2 kt/v) and only 6 (9%) had less than optimal hemodialysis adequacy (kt/v <0.8). Factors associated with hemodialysis adequacy were hospital settings (p = .010), age (p = .007), BMI (p =.004) and blood pressure level ((p = .018). Moreover, mode of transport and type of drinking water was significantly associated with hemodialysis adequacy (p = 0.032 and 0.030 respectively). In conclusion, the level of hemodialysis adequacy was low in 38% of ESRD patients with associated factors predominantly demographics. Therefore, further research inquiry is needed on additional factors which include technical aspects to establish their association with hemodialysis adequacy.

Key concepts: Hemodialysis, Medicine, Dialysis adequacy, Dialysis, End stage renal disease, Demographics, Internal medicine, Intensive care medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Factors associated with hemodialysis adequacy among end stage renal disease patients on maintenance hemodialysis in Rwanda — Research Paper | ScholarLens