2021•Academic Platform Journal of Natural Hazards and Disaster ManagementOpen access

The Risk Calculation of Hazardous Zones Created By Flammable And Explosive Chemicals, LPG Tank Example

Bülent Büyükkıdan, Hüseyin Gümüş, Ömer Ahmet USLU

Open full text 4 citations

Abstract

The determining of hazardous areas created by flammable and explosive chemicals is important to obtain a safe working environment. Taking precautions and prevent explosions require detailed investigations and accurate calculations instead of superficial and personal experience. In this context, possible leakages and leaks occurring around the LPG tank and its connections in a real enterprise were evaluated and the border of possible explosive atmosphere areas was calculated by the ALOAH program according to the TS 60079-10-1 standard. Based on the secondary discharge of the LPG from the bottom of the tank, the discharge characteristics were calculated as 4.946578 3.926692 m3/s at sonic and subsonic conditions respectively, and region radii, 10.8 m. The explosive atmosphere of the LPG tank was concluded that matched well the definition of Zone 2. The risk severity score of explosive atmospheres was calculated as 12 by using the risk assessment method of matrix system with approximations, possible in a week (3P), and the effect that could cause serious injury (4P). Serious threats and devastating effects were fictionalized clearly by explosion scenarios of the LPG tank. The calculations of explosive borders for flammable chemicals are necessary to prevent explosions, fires, and toxic effects of leaked chemicals by taking measurements on time. It is also necessary to calculate explosive areas and possible sceneries for each chemical separately for accurate results and effective control.

Open-access reader

About this research paper

What this paper is about

The determining of hazardous areas created by flammable and explosive chemicals is important to obtain a safe working environment. Taking precautions and prevent explosions require detailed investigations and accurate calculations instead of superficial and personal experience. In this context, possible leakages and leaks occurring around the LPG tank and its connections in a real enterprise were evaluated and the border of possible explosive atmosphere areas was calculated by the ALOAH program according to the TS 60079-10-1 standard. Based on the secondary discharge of the LPG from the bottom of the tank, the discharge characteristics were calculated as 4.946578 3.926692 m3/s at sonic and subsonic conditions respectively, and region radii, 10.8 m. The explosive atmosphere of the LPG tank was concluded that matched well the definition of Zone 2. The risk severity score of explosive atmospheres was calculated as 12 by using the risk assessment method of matrix system with approximations, possible in a week (3P), and the effect that could cause serious injury (4P). Serious threats and devastating effects were fictionalized clearly by explosion scenarios of the LPG tank. The calculations of explosive borders for flammable chemicals are necessary to prevent explosions, fires, and toxic effects of leaked chemicals by taking measurements on time. It is also necessary to calculate explosive areas and possible sceneries for each chemical separately for accurate results and effective control.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The determining of hazardous areas created by flammable and explosive chemicals is important to obtain a safe working environment. Taking precautions and prevent explosions require detailed investigations and accurate calculations instead of superficial and personal experience. In this context, possible leakages and leaks occurring around the LPG tank and its connections in a real enterprise were evaluated and the border of possible explosive atmosphere areas was calculated by the ALOAH program according to the TS 60079-10-1 standard. Based on the secondary discharge of the LPG from the bottom of the tank, the discharge characteristics were calculated as 4.946578 3.926692 m3/s at sonic and subsonic conditions respectively, and region radii, 10.8 m. The explosive atmosphere of the LPG tank was concluded that matched well the definition of Zone 2. The risk severity score of explosive atmospheres was calculated as 12 by using the risk assessment method of matrix system with approximations, possible in a week (3P), and the effect that could cause serious injury (4P). Serious threats and devastating effects were fictionalized clearly by explosion scenarios of the LPG tank. The calculations of explosive borders for flammable chemicals are necessary to prevent explosions, fires, and toxic effects of leaked chemicals by taking measurements on time. It is also necessary to calculate explosive areas and possible sceneries for each chemical separately for accurate results and effective control.

Key concepts: Flammable liquid, Explosive material, Hazardous waste, Environmental science, Flammability limit, Context (archaeology), Hazardous substance, Personal protective equipment

Related papers

Back to paper searchBrowse research topicsOriginal source
The Risk Calculation of Hazardous Zones Created By Flammable And Explosive Chemicals, LPG Tank Example — Research Paper | ScholarLens