2021Turkish Journal of BiochemistryOpen access

Determination of reference ranges for automated erythrocyte and reticulocyte parameters in healthy adults

Esra Fırat Oğuz, Mesude Falay, Müjgan Ercan, Andaç Uzdoğan, Emiş Deniz Akbulut, Gülsüm Özet, Turan Turhan

Open full text 2 citations

Abstract

Abstract Objectives Recent advances in hematology analyzers have enabled to improve the reliability in the results and also provided additional hematological parameters. In the present study, we aimed to determine the reference ranges for automated erythrocyte and reticulocyte parameters in healthy individuals on Sysmex XN 1000 hematology analyzer. Methods One hundred and thirty-three subjects with normal physical examination and complete blood count results within the reference ranges were included in the study. Venous blood samples collected in tubes containing K 2 -EDTA were analyzed on Sysmex XN-1000. The references intervals for IRF, RBC He, Ret He, LFR, MFR, HFR, Delta He, Micro R, Macro R, Hypo He and Hyper He were determined according to CLSI EP28-A3c. Results The reference ranges of the parameters were estimated with 90% confidence intervals. The reference ranges were 3.4–17% for IRF, 26.9–32.8 pg for Ret-He, 25.2–30.5 pg for RBC-He and 0.5–3.7 pg for delta-He. Gender specific reference ranges were calculated for of Ret-He (male (M): 26.8–32.9 pg, female (F): 23.9–33.6 pg), RBC-He (M: 26.3–30.8 pg, F: 25.3–30.5 pg) and delta-He (M: 0.5–3.7 pg, F: 0.3–3.7 pg). Conclusions The new reticulocyte and erythrocyte parameters may be conveniently used in clinical diagnosis and follow-up of patients, as they offer reliable, automated and cheap results. Each laboratory is recommended to determine its own reference intervals considering the differences like the instrument used and population studied.

Open-access reader

About this research paper

What this paper is about

Abstract Objectives Recent advances in hematology analyzers have enabled to improve the reliability in the results and also provided additional hematological parameters. In the present study, we aimed to determine the reference ranges for automated erythrocyte and reticulocyte parameters in healthy individuals on Sysmex XN 1000 hematology analyzer. Methods One hundred and thirty-three subjects with normal physical examination and complete blood count results within the reference ranges were included in the study. Venous blood samples collected in tubes containing K 2 -EDTA were analyzed on Sysmex XN-1000. The references intervals for IRF, RBC He, Ret He, LFR, MFR, HFR, Delta He, Micro R, Macro R, Hypo He and Hyper He were determined according to CLSI EP28-A3c. Results The reference ranges of the parameters were estimated with 90% confidence intervals. The reference ranges were 3.4–17% for IRF, 26.9–32.8 pg for Ret-He, 25.2–30.5 pg for RBC-He and 0.5–3.7 pg for delta-He. Gender specific reference ranges were calculated for of Ret-He (male (M): 26.8–32.9 pg, female (F): 23.9–33.6 pg), RBC-He (M: 26.3–30.8 pg, F: 25.3–30.5 pg) and delta-He (M: 0.5–3.7 pg, F: 0.3–3.7 pg). Conclusions The new reticulocyte and erythrocyte parameters may be conveniently used in clinical diagnosis and follow-up of patients, as they offer reliable, automated and cheap results. Each laboratory is recommended to determine its own reference intervals considering the differences like the instrument used and population studied.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Objectives Recent advances in hematology analyzers have enabled to improve the reliability in the results and also provided additional hematological parameters. In the present study, we aimed to determine the reference ranges for automated erythrocyte and reticulocyte parameters in healthy individuals on Sysmex XN 1000 hematology analyzer. Methods One hundred and thirty-three subjects with normal physical examination and complete blood count results within the reference ranges were included in the study. Venous blood samples collected in tubes containing K 2 -EDTA were analyzed on Sysmex XN-1000. The references intervals for IRF, RBC He, Ret He, LFR, MFR, HFR, Delta He, Micro R, Macro R, Hypo He and Hyper He were determined according to CLSI EP28-A3c. Results The reference ranges of the parameters were estimated with 90% confidence intervals. The reference ranges were 3.4–17% for IRF, 26.9–32.8 pg for Ret-He, 25.2–30.5 pg for RBC-He and 0.5–3.7 pg for delta-He. Gender specific reference ranges were calculated for of Ret-He (male (M): 26.8–32.9 pg, female (F): 23.9–33.6 pg), RBC-He (M: 26.3–30.8 pg, F: 25.3–30.5 pg) and delta-He (M: 0.5–3.7 pg, F: 0.3–3.7 pg). Conclusions The new reticulocyte and erythrocyte parameters may be conveniently used in clinical diagnosis and follow-up of patients, as they offer reliable, automated and cheap results. Each laboratory is recommended to determine its own reference intervals considering the differences like the instrument used and population studied.

Key concepts: Hematology analyzer, Reticulocyte, Reference range, Reference values, Hematology, Limits of agreement, Medicine, Confidence interval

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of reference ranges for automated erythrocyte and reticulocyte parameters in healthy adults — Research Paper | ScholarLens