2013Bangladesh Journal of MedicineOpen access

Reticulocyte Parameter Analysis in the Automated Haematology Analyzer used in the Laboratories

Mst Shaila Yesmin, Tuhin Sultana, Chandan Kumar Roy, Md Quddusur Rahman, AN Nashimuddin Ahmed

Open full text 1 citations

Abstract

Background: Reticulocyte count with immature reticulocyte fraction (IRF) used in the laboratories to evaluate the bone marrow erythropoietic activity and have great diagnostic and prognostic importance in the treatment of anemias and other pathological conditions. Objective: The aim of this study was to establish the normal reference range for reticulocyte count and its parameter. Methods: In this study reticulocyte profile were evaluated by automated analysis in 40 healthy control subjects by XT-2000i (Sysmex) hematology analyzer and compared with measurements obtained by manual methods. Manually reticulocytes were supravitally stained with new methylene blue. Results: This study found MRC was 0.81 ±0.46%. The FCMR was 0.97±0.17%, Ret abs was found .04±.02(106/ ?l) and IRF was found 3.92±1.35%. Conclusion: The precision of the automated analyzer was found significantly higher than the manual methods. DOI: http://dx.doi.org/10.3329/bjmed.v21i2.13616 Bangladesh J Medicine 2010; 21: 80-83

Open-access reader

About this research paper

What this paper is about

Background: Reticulocyte count with immature reticulocyte fraction (IRF) used in the laboratories to evaluate the bone marrow erythropoietic activity and have great diagnostic and prognostic importance in the treatment of anemias and other pathological conditions. Objective: The aim of this study was to establish the normal reference range for reticulocyte count and its parameter. Methods: In this study reticulocyte profile were evaluated by automated analysis in 40 healthy control subjects by XT-2000i (Sysmex) hematology analyzer and compared with measurements obtained by manual methods. Manually reticulocytes were supravitally stained with new methylene blue. Results: This study found MRC was 0.81 ±0.46%. The FCMR was 0.97±0.17%, Ret abs was found .04±.02(106/ ?l) and IRF was found 3.92±1.35%. Conclusion: The precision of the automated analyzer was found significantly higher than the manual methods. DOI: http://dx.doi.org/10.3329/bjmed.v21i2.13616 Bangladesh J Medicine 2010; 21: 80-83

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Reticulocyte count with immature reticulocyte fraction (IRF) used in the laboratories to evaluate the bone marrow erythropoietic activity and have great diagnostic and prognostic importance in the treatment of anemias and other pathological conditions. Objective: The aim of this study was to establish the normal reference range for reticulocyte count and its parameter. Methods: In this study reticulocyte profile were evaluated by automated analysis in 40 healthy control subjects by XT-2000i (Sysmex) hematology analyzer and compared with measurements obtained by manual methods. Manually reticulocytes were supravitally stained with new methylene blue. Results: This study found MRC was 0.81 ±0.46%. The FCMR was 0.97±0.17%, Ret abs was found .04±.02(106/ ?l) and IRF was found 3.92±1.35%. Conclusion: The precision of the automated analyzer was found significantly higher than the manual methods. DOI: http://dx.doi.org/10.3329/bjmed.v21i2.13616 Bangladesh J Medicine 2010; 21: 80-83

Key concepts: Reticulocyte, Hematology analyzer, Medicine, Spectrum analyzer, Hematology, Blood count, Bone marrow, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Reticulocyte Parameter Analysis in the Automated Haematology Analyzer used in the Laboratories — Research Paper | ScholarLens