2021PubMedOpen access

The diagnostic value of high-frequency ultrasound combined with color Doppler ultrasound versus surgical pathology in gallbladder polyps.

Yanli Li, Yintai Wang, Mingyan Chi

Open full text 8 citations

Abstract

OBJECTIVE: This study aimed to analyze the value of high-frequency ultrasound combined with color Doppler ultrasound in the diagnosis of gallbladder polyps. METHODS: A retrospective analysis was performed on 108 patients with gallbladder polyps, all of whom were examined by high-frequency ultrasound and color Doppler ultrasound with surgical or pathological findings as the gold standard. RESULTS: Taking surgical pathology findings as the gold standard, the diagnostic accuracy, sensitivity and specificity of high-frequency ultrasound for gallbladder polyps were 63.89%, 63.27%, and 70.00%, respectively. The diagnostic accuracy, sensitivity and specificity of color Doppler ultrasound were 74.07%, 73.47%, and 80.00%, respectively. The diagnostic accuracy, sensitivity and specificity of high-frequency ultrasound combined with color Doppler ultrasound were 91.67%, 90.82%, and 100.00%, respectively. The proportion of mulberry-like or papillary projections was 56.18% in 89 benign lesions diagnosed by high-frequency ultrasound combined with color Doppler ultrasound, the proportion of hyperechoic lesion was 47.19%, and the proportion of single lesion was 59.55%. The incidence rate of blood flow signal was 26.97% in 89 benign lesions, including 10 cases of punctiform blood flow signal, 9 cases of band-like blood flow signal and 5 cases of multiple stones in the lumen of the gallbladder. CONCLUSION: High-frequency ultrasound combined with color Doppler ultrasound has high accuracy in the diagnosis of gallbladder polyps, and can yield better diagnostic results than either method, which can be used as an optional method for the diagnosis of gallbladder polyps.

About this research paper

What this paper is about

OBJECTIVE: This study aimed to analyze the value of high-frequency ultrasound combined with color Doppler ultrasound in the diagnosis of gallbladder polyps. METHODS: A retrospective analysis was performed on 108 patients with gallbladder polyps, all of whom were examined by high-frequency ultrasound and color Doppler ultrasound with surgical or pathological findings as the gold standard. RESULTS: Taking surgical pathology findings as the gold standard, the diagnostic accuracy, sensitivity and specificity of high-frequency ultrasound for gallbladder polyps were 63.89%, 63.27%, and 70.00%, respectively. The diagnostic accuracy, sensitivity and specificity of color Doppler ultrasound were 74.07%, 73.47%, and 80.00%, respectively. The diagnostic accuracy, sensitivity and specificity of high-frequency ultrasound combined with color Doppler ultrasound were 91.67%, 90.82%, and 100.00%, respectively. The proportion of mulberry-like or papillary projections was 56.18% in 89 benign lesions diagnosed by high-frequency ultrasound combined with color Doppler ultrasound, the proportion of hyperechoic lesion was 47.19%, and the proportion of single lesion was 59.55%. The incidence rate of blood flow signal was 26.97% in 89 benign lesions, including 10 cases of punctiform blood flow signal, 9 cases of band-like blood flow signal and 5 cases of multiple stones in the lumen of the gallbladder. CONCLUSION: High-frequency ultrasound combined with color Doppler ultrasound has high accuracy in the diagnosis of gallbladder polyps, and can yield better diagnostic results than either method, which can be used as an optional method for the diagnosis of gallbladder polyps.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: This study aimed to analyze the value of high-frequency ultrasound combined with color Doppler ultrasound in the diagnosis of gallbladder polyps. METHODS: A retrospective analysis was performed on 108 patients with gallbladder polyps, all of whom were examined by high-frequency ultrasound and color Doppler ultrasound with surgical or pathological findings as the gold standard. RESULTS: Taking surgical pathology findings as the gold standard, the diagnostic accuracy, sensitivity and specificity of high-frequency ultrasound for gallbladder polyps were 63.89%, 63.27%, and 70.00%, respectively. The diagnostic accuracy, sensitivity and specificity of color Doppler ultrasound were 74.07%, 73.47%, and 80.00%, respectively. The diagnostic accuracy, sensitivity and specificity of high-frequency ultrasound combined with color Doppler ultrasound were 91.67%, 90.82%, and 100.00%, respectively. The proportion of mulberry-like or papillary projections was 56.18% in 89 benign lesions diagnosed by high-frequency ultrasound combined with color Doppler ultrasound, the proportion of hyperechoic lesion was 47.19%, and the proportion of single lesion was 59.55%. The incidence rate of blood flow signal was 26.97% in 89 benign lesions, including 10 cases of punctiform blood flow signal, 9 cases of band-like blood flow signal and 5 cases of multiple stones in the lumen of the gallbladder. CONCLUSION: High-frequency ultrasound combined with color Doppler ultrasound has high accuracy in the diagnosis of gallbladder polyps, and can yield better diagnostic results than either method, which can be used as an optional method for the diagnosis of gallbladder polyps.

Key concepts: Medicine, Ultrasound, Gallbladder, Radiology, Blood flow, Gold standard (test), Color doppler, Doppler effect

Related papers

Back to paper searchBrowse research topicsOriginal source
The diagnostic value of high-frequency ultrasound combined with color Doppler ultrasound versus surgical pathology in gallbladder polyps. — Research Paper | ScholarLens