2021•2021 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)Requires access

Influence of temperature on the performance of Nafion coated RuO2 based pH electrodes

Kiranmai Uppuluri, Maryna Lazouskaya, Dorota Szwagierczak, Krzysztof Zaraska

Open publisher page 1 citations

Abstract

At present, ruthenium oxide (RuO2) based solid-state electrodes are investigated as an alternative to conventional glass electrode due to their low cost, chemical and physical durability, good sensitivity and fast response. Coverage of the solid-state electrodes with a protective membrane can improve the overall performance of the electrode and allow measurement in complex media, such as blood, food, biologically active environment. One of the well-known protective membranes for electrodes is Nafion. However, little is known about the performance of Nafion-covered electrodes used in heated samples. Here we present the investigation of the behaviour of ruthenium oxide (RuO2) based pH electrodes modified with Nafion protective membrane (RuO2-Nafion) at an elevated temperature of 80°C. RuO2 electrodes were fabricated by screen printing technique. We compare the performance of the RuO2-Nafion electrodes was compared to that of unmodified RuO2 electrodes. Both unmodified RuO2 electrodes and RuO2-Nafion electrodes perform well at room temperature, showing sensitivity close to the theoretical value (58.4 and 62.4 mV/pH respectively), the fast response time (14 and 42 s respectively) and low drift rate (0.5 and 0.4 mV/h respectively). The sensitivity of the Nafion- covered electrodes was found to be higher at elevated temperature as well: 37.2 mV/pH compared to 33.4 mV/pH for unmodified electrodes. Furthermore, RuO2-Nafion electrodes showed a lower drift rate at elevated temperature (9.6 mV/h) compared to that of modified electrodes (34.8 mV/h).

About this research paper

What this paper is about

At present, ruthenium oxide (RuO2) based solid-state electrodes are investigated as an alternative to conventional glass electrode due to their low cost, chemical and physical durability, good sensitivity and fast response. Coverage of the solid-state electrodes with a protective membrane can improve the overall performance of the electrode and allow measurement in complex media, such as blood, food, biologically active environment. One of the well-known protective membranes for electrodes is Nafion. However, little is known about the performance of Nafion-covered electrodes used in heated samples. Here we present the investigation of the behaviour of ruthenium oxide (RuO2) based pH electrodes modified with Nafion protective membrane (RuO2-Nafion) at an elevated temperature of 80°C. RuO2 electrodes were fabricated by screen printing technique. We compare the performance of the RuO2-Nafion electrodes was compared to that of unmodified RuO2 electrodes. Both unmodified RuO2 electrodes and RuO2-Nafion electrodes perform well at room temperature, showing sensitivity close to the theoretical value (58.4 and 62.4 mV/pH respectively), the fast response time (14 and 42 s respectively) and low drift rate (0.5 and 0.4 mV/h respectively). The sensitivity of the Nafion- covered electrodes was found to be higher at elevated temperature as well: 37.2 mV/pH compared to 33.4 mV/pH for unmodified electrodes. Furthermore, RuO2-Nafion electrodes showed a lower drift rate at elevated temperature (9.6 mV/h) compared to that of modified electrodes (34.8 mV/h).

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

At present, ruthenium oxide (RuO2) based solid-state electrodes are investigated as an alternative to conventional glass electrode due to their low cost, chemical and physical durability, good sensitivity and fast response. Coverage of the solid-state electrodes with a protective membrane can improve the overall performance of the electrode and allow measurement in complex media, such as blood, food, biologically active environment. One of the well-known protective membranes for electrodes is Nafion. However, little is known about the performance of Nafion-covered electrodes used in heated samples. Here we present the investigation of the behaviour of ruthenium oxide (RuO2) based pH electrodes modified with Nafion protective membrane (RuO2-Nafion) at an elevated temperature of 80°C. RuO2 electrodes were fabricated by screen printing technique. We compare the performance of the RuO2-Nafion electrodes was compared to that of unmodified RuO2 electrodes. Both unmodified RuO2 electrodes and RuO2-Nafion electrodes perform well at room temperature, showing sensitivity close to the theoretical value (58.4 and 62.4 mV/pH respectively), the fast response time (14 and 42 s respectively) and low drift rate (0.5 and 0.4 mV/h respectively). The sensitivity of the Nafion- covered electrodes was found to be higher at elevated temperature as well: 37.2 mV/pH compared to 33.4 mV/pH for unmodified electrodes. Furthermore, RuO2-Nafion electrodes showed a lower drift rate at elevated temperature (9.6 mV/h) compared to that of modified electrodes (34.8 mV/h).

Key concepts: Nafion, Electrode, Materials science, Ruthenium oxide, Ruthenium, Membrane, Analytical Chemistry (journal), Electrochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of temperature on the performance of Nafion coated RuO2 based pH electrodes — Research Paper | ScholarLens