A Fluid Structure Interaction Model of Bileaflet and Monoleaflet Mechanical Heart Valve Flow Dynamics
Morteza Kimiaghalam, David Alan Rubenstein, Wei Yin
Abstract
Morteza Kimiaghalam, David Alan Rubenstein, Wei Yin
Abstract
The goal of the study was to develop a 3D numerical model to evaluate the opening and closing behavior of a monoleaflet and a bileaflet mechanical heart valve in a left‐ventricle simulating flow chamber. A diaphragm located at the bottom of the chamber drove the flow in the chamber to circulate through two mechanical heart valves on each side of the chamber. 3D Fluid Structure Interaction (FSI) approaches (ANSYS) were employed to describe the movement of the diaphragm and the valve leaflets. The opening angle of the bileafelt heart valve was set at 85°, and that of the monoleaflet heart valve varied between 45° and 85°. Hemodynamic performance of these valves were evaluated by maximum flow velocity through the valve, average pressure gradient across the valve, valve opening and closing time, and effective orifice area. The results demonstrated that the 3D numerical model was able to accurately simulate the opening and closing of these heart valves. The hemodynamic performance of the monoleaflet heart valve was heavily dependent on the opening angle. An opening angle between 75° to 80° provided the best hemodynamic performance of the monoleaflet heart valve. At this angle, the flow conditions around the monoleaflet valve was slightly better than that around the bileaflet valve, with a large effective orifice area, lower maximum flow velocity, and lower average transvalvular pressure. This work is supported by NSF‐DMR0907291.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The goal of the study was to develop a 3D numerical model to evaluate the opening and closing behavior of a monoleaflet and a bileaflet mechanical heart valve in a left‐ventricle simulating flow chamber. A diaphragm located at the bottom of the chamber drove the flow in the chamber to circulate through two mechanical heart valves on each side of the chamber. 3D Fluid Structure Interaction (FSI) approaches (ANSYS) were employed to describe the movement of the diaphragm and the valve leaflets. The opening angle of the bileafelt heart valve was set at 85°, and that of the monoleaflet heart valve varied between 45° and 85°. Hemodynamic performance of these valves were evaluated by maximum flow velocity through the valve, average pressure gradient across the valve, valve opening and closing time, and effective orifice area. The results demonstrated that the 3D numerical model was able to accurately simulate the opening and closing of these heart valves. The hemodynamic performance of the monoleaflet heart valve was heavily dependent on the opening angle. An opening angle between 75° to 80° provided the best hemodynamic performance of the monoleaflet heart valve. At this angle, the flow conditions around the monoleaflet valve was slightly better than that around the bileaflet valve, with a large effective orifice area, lower maximum flow velocity, and lower average transvalvular pressure. This work is supported by NSF‐DMR0907291.
Key concepts: Body orifice, Ventricle, Hemodynamics, Fluid–structure interaction, Mechanical heart-valve, Heart valve, Pressure gradient, Materials science