2021AIP conference proceedingsRequires access

Characterization of flow rate and heat loss in heating, ventilation and air conditioning (HVAC) duct system for office building

Nik Normunira Mat Hassan, Abdul Mutalib Leman, Muhammad Alif Mohamed Noor Zafarullah, Zuliazura Mohd Salleh, Khairul Anuar Abdul Rahman, Rais Hanizam Madon, Syafiq Muzarpar, A. R. Shayfull Zamree

Open publisher page 4 citations

Abstract

A building is an assemblage that is firmly attached to the ground and provides the performance of human activities and need to be considered in the daily operation in that building. The improvements in building performance are focused on improving the energy efficiency of buildings. This is approach by designing heating, ventilation and air conditioning (HVAC) duct system due to one of the most utilized energy in maintaining building performance and environment. The objectives of this research is to calculate the air (CFM) supply in office building, to characterize the velocity and head loss in a round and rectangular HVAC ducting system at various duct thickness and to optimize the thickness of the duct in HVAC system according to ASHRAE Standard. The increasing of velocity in duct system shows the increasing of head loss. The round duct design gives the lowest velocity and head loss in HVAC system approximately around 9.35% as compared to rectangular duct at 0.06 inches thickness. Hence, the trends of the head loss and duct thickness has influenced in reducing noise in HVAC duct system in order to select the best design concepts which is round shape design.

About this research paper

What this paper is about

A building is an assemblage that is firmly attached to the ground and provides the performance of human activities and need to be considered in the daily operation in that building. The improvements in building performance are focused on improving the energy efficiency of buildings. This is approach by designing heating, ventilation and air conditioning (HVAC) duct system due to one of the most utilized energy in maintaining building performance and environment. The objectives of this research is to calculate the air (CFM) supply in office building, to characterize the velocity and head loss in a round and rectangular HVAC ducting system at various duct thickness and to optimize the thickness of the duct in HVAC system according to ASHRAE Standard. The increasing of velocity in duct system shows the increasing of head loss. The round duct design gives the lowest velocity and head loss in HVAC system approximately around 9.35% as compared to rectangular duct at 0.06 inches thickness. Hence, the trends of the head loss and duct thickness has influenced in reducing noise in HVAC duct system in order to select the best design concepts which is round shape design.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A building is an assemblage that is firmly attached to the ground and provides the performance of human activities and need to be considered in the daily operation in that building. The improvements in building performance are focused on improving the energy efficiency of buildings. This is approach by designing heating, ventilation and air conditioning (HVAC) duct system due to one of the most utilized energy in maintaining building performance and environment. The objectives of this research is to calculate the air (CFM) supply in office building, to characterize the velocity and head loss in a round and rectangular HVAC ducting system at various duct thickness and to optimize the thickness of the duct in HVAC system according to ASHRAE Standard. The increasing of velocity in duct system shows the increasing of head loss. The round duct design gives the lowest velocity and head loss in HVAC system approximately around 9.35% as compared to rectangular duct at 0.06 inches thickness. Hence, the trends of the head loss and duct thickness has influenced in reducing noise in HVAC duct system in order to select the best design concepts which is round shape design.

Key concepts: HVAC, Duct (anatomy), ASHRAE 90.1, Atmospheric duct, Air conditioning, Airflow, Engineering, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Characterization of flow rate and heat loss in heating, ventilation and air conditioning (HVAC) duct system for office building — Research Paper | ScholarLens