Quantifying the nationwide HVAC energy savings in large hotels: the role of occupant-centric controls
Zhihong Pang, Yan Chen, Jian Zhang, Zheng O’Neill, Hwakong Cheng, Bing Dong
Abstract
Zhihong Pang, Yan Chen, Jian Zhang, Zheng O’Neill, Hwakong Cheng, Bing Dong
Abstract
This paper presents a nationwide simulation study to investigate the HVAC energy savings potential of occupancy sensors and occupant-centric controls (OCCs) in large hotel buildings. Three simulation scenarios were defined to reflect the different levels of occupancy sensing capabilities. Multiple zone-level and system-level occupant-centric HVAC control strategies were extracted from the updated ASHRAE Standard 90.1 – 2016 and 90.1 – 2019 to facilitate the control purpose. 19 climate zones defined in the International Energy Conservation Code and two versions of ASHRAE Standard 90.1 were considered to include the diversities of climates and building vintage. The simulation results showed that the HVAC energy savings ratios varied from 24% to 58% depending on the sensor type, local climate zone, and version of building energy code. It was also found that the occupant counting sensor could achieve an additional 5%–15% HVAC energy savings for the whole building compared with the presence sensors.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper presents a nationwide simulation study to investigate the HVAC energy savings potential of occupancy sensors and occupant-centric controls (OCCs) in large hotel buildings. Three simulation scenarios were defined to reflect the different levels of occupancy sensing capabilities. Multiple zone-level and system-level occupant-centric HVAC control strategies were extracted from the updated ASHRAE Standard 90.1 – 2016 and 90.1 – 2019 to facilitate the control purpose. 19 climate zones defined in the International Energy Conservation Code and two versions of ASHRAE Standard 90.1 were considered to include the diversities of climates and building vintage. The simulation results showed that the HVAC energy savings ratios varied from 24% to 58% depending on the sensor type, local climate zone, and version of building energy code. It was also found that the occupant counting sensor could achieve an additional 5%–15% HVAC energy savings for the whole building compared with the presence sensors.
Key concepts: ASHRAE 90.1, HVAC, Occupancy, Energy (signal processing), Architectural engineering, Building energy simulation, Efficient energy use, Automotive engineering