Catheter ablation of accessory pathways with a direct approach. Results in 35 patients.
J FWarin, MHaissaguerre, PLemetayer, J PGuillem, PBlanchot
Abstract
J FWarin, MHaissaguerre, PLemetayer, J PGuillem, PBlanchot
Abstract
Thirty-five consecutive patients with an overt accessory pathway, all but two suffering from arrhythmia (atrial fibrillation, reciprocating tachycardia, or both), underwent attempted transcatheter ablation (fulguration) of their accessory pathway. Thirty-three patients had been treated with a mean of 2.3 +/- 1.4 antiarrhythmic drugs. A standard bipolar catheter was positioned on the internal surface of the right or left atrioventricular anulus with 1) a subclavian approach of the right cardiac cavities in 29 patients with right-sided accessory pathway (n = 27) or left posteroseptal accessory pathway (n = 2), 2) a patent foramen ovale in five patients (two with a left posterolateral accessory pathway and three with a left parietal accessory pathway), and a transseptal catheterism (one patient with a left parietal accessory pathway). Cathodic shocks (mean, 4.3 shocks/patient) with a mean cumulative energy of 690 J enabled the ablation (disappearance of both anterograde and retrograde conduction) of the acce...
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Thirty-five consecutive patients with an overt accessory pathway, all but two suffering from arrhythmia (atrial fibrillation, reciprocating tachycardia, or both), underwent attempted transcatheter ablation (fulguration) of their accessory pathway. Thirty-three patients had been treated with a mean of 2.3 +/- 1.4 antiarrhythmic drugs. A standard bipolar catheter was positioned on the internal surface of the right or left atrioventricular anulus with 1) a subclavian approach of the right cardiac cavities in 29 patients with right-sided accessory pathway (n = 27) or left posteroseptal accessory pathway (n = 2), 2) a patent foramen ovale in five patients (two with a left posterolateral accessory pathway and three with a left parietal accessory pathway), and a transseptal catheterism (one patient with a left parietal accessory pathway). Cathodic shocks (mean, 4.3 shocks/patient) with a mean cumulative energy of 690 J enabled the ablation (disappearance of both anterograde and retrograde conduction) of the acce...
Key concepts: Accessory pathway, Medicine, Fulguration, Catheter ablation, Ablation, Cardiology, Internal medicine, Tachycardia