The contents of Mg,Al,Si,Ti,Cr,Mn,Fe,Co,Cu,Ga,As,Se,Cd,Sb,Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry(HR-ICP-MS).The sample was dissolved in HNO3 and HCl by microwave digestion.Most of the spectral interferences could be avoided by measuring in the high resolution mode.The matrix effects because of the presence of excess HCl and nickel were evaluated.Correction for matrix effects was made using Sc,Rh and Tl as internal standards.The optimum conditions for the determination were tested and discussed.The detection limits range from 0.012 to 1.76 μg/g depending on the type of elements.The applicability of the proposed method is also validated by the analysis of high purity nickel reference material(NIST SRM 671).The relative standard deviation(RSD) is less than 3.3%.Results for determination of trace elements in high purity nickel were presented.

About this research paper

What this paper is about

The contents of Mg,Al,Si,Ti,Cr,Mn,Fe,Co,Cu,Ga,As,Se,Cd,Sb,Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry(HR-ICP-MS).The sample was dissolved in HNO3 and HCl by microwave digestion.Most of the spectral interferences could be avoided by measuring in the high resolution mode.The matrix effects because of the presence of excess HCl and nickel were evaluated.Correction for matrix effects was made using Sc,Rh and Tl as internal standards.The optimum conditions for the determination were tested and discussed.The detection limits range from 0.012 to 1.76 μg/g depending on the type of elements.The applicability of the proposed method is also validated by the analysis of high purity nickel reference material(NIST SRM 671).The relative standard deviation(RSD) is less than 3.3%.Results for determination of trace elements in high purity nickel were presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The contents of Mg,Al,Si,Ti,Cr,Mn,Fe,Co,Cu,Ga,As,Se,Cd,Sb,Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry(HR-ICP-MS).The sample was dissolved in HNO3 and HCl by microwave digestion.Most of the spectral interferences could be avoided by measuring in the high resolution mode.The matrix effects because of the presence of excess HCl and nickel were evaluated.Correction for matrix effects was made using Sc,Rh and Tl as internal standards.The optimum conditions for the determination were tested and discussed.The detection limits range from 0.012 to 1.76 μg/g depending on the type of elements.The applicability of the proposed method is also validated by the analysis of high purity nickel reference material(NIST SRM 671).The relative standard deviation(RSD) is less than 3.3%.Results for determination of trace elements in high purity nickel were presented.

Key concepts: Inductively coupled plasma mass spectrometry, Nickel, Analytical Chemistry (journal), Chemistry, Mass spectrometry, Inductively coupled plasma, Detection limit, Matrix (chemical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry — Research Paper | ScholarLens