Determination of trace elements in high-purity nickel by inductively coupled plasma mass spectrometry with microwave digestion

Yong Cheng

Open publisher page 0 citations

Abstract

A method for simultaneous direct determination of thirteen trace elements in high-purity nickel including Si,P,Fe,Cu,Zn,As,Cd,Sn,Sb,Pb,Al,Mn,Mg by inductively coupled plasma mass spectrometry(ICP-MS) with microwave digestion has been established.The conditions of microwave digestion,the matrix effect and spectral interferences were investigated,and the operating parameters of the ICP ionization source,mass spectrometry and microwave digestion were optimized.It was found that the matrix effect could be eliminated by matching matrix or selecting Sc,Rh as internal standard element and the spectral interference could be calibrated by selecting different isotope or correction equation of interference elements.The detection limits range of the method is from 0.01 to 0.05 μg/L for thirteen trace elements.The precision and recovery tests were made and the results obtained were as follows: the recoveries in the range 92.0%-112.0% and RSD 8.5 %.The determination results of actual samples are consistent with those obtained by other methods.

About this research paper

What this paper is about

A method for simultaneous direct determination of thirteen trace elements in high-purity nickel including Si,P,Fe,Cu,Zn,As,Cd,Sn,Sb,Pb,Al,Mn,Mg by inductively coupled plasma mass spectrometry(ICP-MS) with microwave digestion has been established.The conditions of microwave digestion,the matrix effect and spectral interferences were investigated,and the operating parameters of the ICP ionization source,mass spectrometry and microwave digestion were optimized.It was found that the matrix effect could be eliminated by matching matrix or selecting Sc,Rh as internal standard element and the spectral interference could be calibrated by selecting different isotope or correction equation of interference elements.The detection limits range of the method is from 0.01 to 0.05 μg/L for thirteen trace elements.The precision and recovery tests were made and the results obtained were as follows: the recoveries in the range 92.0%-112.0% and RSD 8.5 %.The determination results of actual samples are consistent with those obtained by other methods.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for simultaneous direct determination of thirteen trace elements in high-purity nickel including Si,P,Fe,Cu,Zn,As,Cd,Sn,Sb,Pb,Al,Mn,Mg by inductively coupled plasma mass spectrometry(ICP-MS) with microwave digestion has been established.The conditions of microwave digestion,the matrix effect and spectral interferences were investigated,and the operating parameters of the ICP ionization source,mass spectrometry and microwave digestion were optimized.It was found that the matrix effect could be eliminated by matching matrix or selecting Sc,Rh as internal standard element and the spectral interference could be calibrated by selecting different isotope or correction equation of interference elements.The detection limits range of the method is from 0.01 to 0.05 μg/L for thirteen trace elements.The precision and recovery tests were made and the results obtained were as follows: the recoveries in the range 92.0%-112.0% and RSD 8.5 %.The determination results of actual samples are consistent with those obtained by other methods.

Key concepts: Microwave digestion, Inductively coupled plasma mass spectrometry, Chemistry, Analytical Chemistry (journal), Mass spectrometry, Matrix (chemical analysis), Inductively coupled plasma, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace elements in high-purity nickel by inductively coupled plasma mass spectrometry with microwave digestion — Research Paper | ScholarLens