2008•DOAJ (DOAJ: Directory of Open Access Journals)Open access

Determination of Pioglitazone Hydrochloride in Tablets by High-Performance Liquid Chromatography

Amr Lotfy Saber

Open full text 14 citations

Abstract

A rapid and accurate HPLC method has been developed for the determination of pioglitazone hydrochloride in tablets. Chromatographic analysis was performed on a Nova-Pak® C18 column (3.9mm x 150mm, 5µm) with a mixture of ammonium formate buffer adjusted with formic acid to pH 3 and acetonitrile (75:25, v/v) as mobile phase, at flow rate of 1.0 mL min-1, and UV detection at 225 nm. The determination was completed in less than 12 min. Linearity ≥ 0.5 µgmL-1, accuracy ≥ 99.14 %, and precision ≤ 0.6 % were found to be acceptable over the range 0.5 - 20 µgmL-1.

About this research paper

What this paper is about

A rapid and accurate HPLC method has been developed for the determination of pioglitazone hydrochloride in tablets. Chromatographic analysis was performed on a Nova-Pak® C18 column (3.9mm x 150mm, 5µm) with a mixture of ammonium formate buffer adjusted with formic acid to pH 3 and acetonitrile (75:25, v/v) as mobile phase, at flow rate of 1.0 mL min-1, and UV detection at 225 nm. The determination was completed in less than 12 min. Linearity ≥ 0.5 µgmL-1, accuracy ≥ 99.14 %, and precision ≤ 0.6 % were found to be acceptable over the range 0.5 - 20 µgmL-1.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid and accurate HPLC method has been developed for the determination of pioglitazone hydrochloride in tablets. Chromatographic analysis was performed on a Nova-Pak® C18 column (3.9mm x 150mm, 5µm) with a mixture of ammonium formate buffer adjusted with formic acid to pH 3 and acetonitrile (75:25, v/v) as mobile phase, at flow rate of 1.0 mL min-1, and UV detection at 225 nm. The determination was completed in less than 12 min. Linearity ≥ 0.5 µgmL-1, accuracy ≥ 99.14 %, and precision ≤ 0.6 % were found to be acceptable over the range 0.5 - 20 µgmL-1.

Key concepts: Pioglitazone, Chromatography, Hydrochloride, High-performance liquid chromatography, Chemistry, Medicine, Organic chemistry, Endocrinology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Pioglitazone Hydrochloride in Tablets by High-Performance Liquid Chromatography — Research Paper | ScholarLens