Development and Validation of a Simple and Rapid HPLC Method for Determination of Pioglitazone in Human Plasma and its Application to a Pharmacokinetic Study

Effat Souri, Hassan Jalalizadeh, Shahrooz Saremi

Open full text 36 citations

Abstract

In this study, a new, simple, and reproducible high-performance liquid chromatographic method was developed for the determination of pioglitazone in human plasma. After liquid-liquid extraction with diethylether, samples were quantitated on a Nova-Pak C8 column using a mixture of acetonitrile-140mM K2HPO4 (40:60, v/v, pH = 4.45) as mobile phase with UV detection at 269 nm. The flow rate was set at 1.4 mL/min. Ethylparaben was used as internal standard and the total run time of analysis was approximately 7 min. The method was linear over the range of 25-1500 ng/mL of pioglitazone in plasma (r2 > 0.999). The within- and between-day precision values were in the range of 2.4-6.8%. The limit of quantitation of the method was 25 ng/mL. The method was successfully used to study the pharmacokinetics of pioglitazone in healthy volunteers.

Open-access reader

About this research paper

What this paper is about

In this study, a new, simple, and reproducible high-performance liquid chromatographic method was developed for the determination of pioglitazone in human plasma. After liquid-liquid extraction with diethylether, samples were quantitated on a Nova-Pak C8 column using a mixture of acetonitrile-140mM K2HPO4 (40:60, v/v, pH = 4.45) as mobile phase with UV detection at 269 nm. The flow rate was set at 1.4 mL/min. Ethylparaben was used as internal standard and the total run time of analysis was approximately 7 min. The method was linear over the range of 25-1500 ng/mL of pioglitazone in plasma (r2 > 0.999). The within- and between-day precision values were in the range of 2.4-6.8%. The limit of quantitation of the method was 25 ng/mL. The method was successfully used to study the pharmacokinetics of pioglitazone in healthy volunteers.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, a new, simple, and reproducible high-performance liquid chromatographic method was developed for the determination of pioglitazone in human plasma. After liquid-liquid extraction with diethylether, samples were quantitated on a Nova-Pak C8 column using a mixture of acetonitrile-140mM K2HPO4 (40:60, v/v, pH = 4.45) as mobile phase with UV detection at 269 nm. The flow rate was set at 1.4 mL/min. Ethylparaben was used as internal standard and the total run time of analysis was approximately 7 min. The method was linear over the range of 25-1500 ng/mL of pioglitazone in plasma (r2 > 0.999). The within- and between-day precision values were in the range of 2.4-6.8%. The limit of quantitation of the method was 25 ng/mL. The method was successfully used to study the pharmacokinetics of pioglitazone in healthy volunteers.

Key concepts: Pioglitazone, Chromatography, Chemistry, Pharmacokinetics, High-performance liquid chromatography, Extraction (chemistry), Detection limit, Linear range