Development and Validation of a Simple and Rapid HPLC Method for Determination of Pioglitazone in Human Plasma and its Application to a Pharmacokinetic Study
Effat Souri, Hassan Jalalizadeh, Shahrooz Saremi
Abstract
Open-access reader
Effat Souri, Hassan Jalalizadeh, Shahrooz Saremi
Abstract
Open-access reader
In this study, a new, simple, and reproducible high-performance liquid chromatographic method was developed for the determination of pioglitazone in human plasma. After liquid-liquid extraction with diethylether, samples were quantitated on a Nova-Pak C8 column using a mixture of acetonitrile-140mM K2HPO4 (40:60, v/v, pH = 4.45) as mobile phase with UV detection at 269 nm. The flow rate was set at 1.4 mL/min. Ethylparaben was used as internal standard and the total run time of analysis was approximately 7 min. The method was linear over the range of 25-1500 ng/mL of pioglitazone in plasma (r2 > 0.999). The within- and between-day precision values were in the range of 2.4-6.8%. The limit of quantitation of the method was 25 ng/mL. The method was successfully used to study the pharmacokinetics of pioglitazone in healthy volunteers.
OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this study, a new, simple, and reproducible high-performance liquid chromatographic method was developed for the determination of pioglitazone in human plasma. After liquid-liquid extraction with diethylether, samples were quantitated on a Nova-Pak C8 column using a mixture of acetonitrile-140mM K2HPO4 (40:60, v/v, pH = 4.45) as mobile phase with UV detection at 269 nm. The flow rate was set at 1.4 mL/min. Ethylparaben was used as internal standard and the total run time of analysis was approximately 7 min. The method was linear over the range of 25-1500 ng/mL of pioglitazone in plasma (r2 > 0.999). The within- and between-day precision values were in the range of 2.4-6.8%. The limit of quantitation of the method was 25 ng/mL. The method was successfully used to study the pharmacokinetics of pioglitazone in healthy volunteers.
Key concepts: Pioglitazone, Chromatography, Chemistry, Pharmacokinetics, High-performance liquid chromatography, Extraction (chemistry), Detection limit, Linear range