2009•Journal of environmental healthRequires access

Determination of Carbaryl and Atrazine in Water with Solid Phase Extraction-High Performance Liquid Chromatography

Liu Xiang-pin

Open publisher page 0 citations

Abstract

Objective To establish a SPE-HPLC method for the determination of carbaryl and atrazine in water.Methods Carbaryl and atrazine in water were extracted with Oasis HLB and were eluted with CH3OH,CH3OH-H2O(55:45) was applied as mobile phase,the flow rate was 0.8 ml/min,detection wavelength was 220 nm,column was Symmetry Shield RP18(150 mm × 3.9 mm,5 μm),carbaryl and atrazine in water were determined by PDA detector.Results The linear range of the method was 0.05-10.0 mg/L(y=316 263x-350 9,r=0.999 9,for carbary;y=140 151x-258 6,r=0.999 9,for atrazine),The lowest detected concentration was 0.0002 mg/L for carbary and 0.000 5 mg/L for atrazine,respectively(S/N≥3).The recovery rates were 89.6%-97.0%,and the relative standard deviation was 4.0%-6.7%.Conclusion The method was sensitive,accurate and repeatable,which was applicable to the determination of carbaryl and atrazine in water.

About this research paper

What this paper is about

Objective To establish a SPE-HPLC method for the determination of carbaryl and atrazine in water.Methods Carbaryl and atrazine in water were extracted with Oasis HLB and were eluted with CH3OH,CH3OH-H2O(55:45) was applied as mobile phase,the flow rate was 0.8 ml/min,detection wavelength was 220 nm,column was Symmetry Shield RP18(150 mm × 3.9 mm,5 μm),carbaryl and atrazine in water were determined by PDA detector.Results The linear range of the method was 0.05-10.0 mg/L(y=316 263x-350 9,r=0.999 9,for carbary;y=140 151x-258 6,r=0.999 9,for atrazine),The lowest detected concentration was 0.0002 mg/L for carbary and 0.000 5 mg/L for atrazine,respectively(S/N≥3).The recovery rates were 89.6%-97.0%,and the relative standard deviation was 4.0%-6.7%.Conclusion The method was sensitive,accurate and repeatable,which was applicable to the determination of carbaryl and atrazine in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a SPE-HPLC method for the determination of carbaryl and atrazine in water.Methods Carbaryl and atrazine in water were extracted with Oasis HLB and were eluted with CH3OH,CH3OH-H2O(55:45) was applied as mobile phase,the flow rate was 0.8 ml/min,detection wavelength was 220 nm,column was Symmetry Shield RP18(150 mm × 3.9 mm,5 μm),carbaryl and atrazine in water were determined by PDA detector.Results The linear range of the method was 0.05-10.0 mg/L(y=316 263x-350 9,r=0.999 9,for carbary;y=140 151x-258 6,r=0.999 9,for atrazine),The lowest detected concentration was 0.0002 mg/L for carbary and 0.000 5 mg/L for atrazine,respectively(S/N≥3).The recovery rates were 89.6%-97.0%,and the relative standard deviation was 4.0%-6.7%.Conclusion The method was sensitive,accurate and repeatable,which was applicable to the determination of carbaryl and atrazine in water.

Key concepts: Carbaryl, Atrazine, Chromatography, Chemistry, High-performance liquid chromatography, Solid phase extraction, Extraction (chemistry), Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Carbaryl and Atrazine in Water with Solid Phase Extraction-High Performance Liquid Chromatography — Research Paper | ScholarLens