Ahmed glaucoma valve implantation in treatment of twelve eyes with glaucoma after vitrectomy:a clinical study
Fan Wang
Abstract
Fan Wang
Abstract
Objective To evaluate the efficacy and safety of Ahmed glaucoma valve implantation for glaucoma following vitrectomy surgery.Methods Twelve patients(12 eyes) who had been diagnosed with glaucoma after vitrectomy and phacoemulsification surgery due to retina detachment were selected in this study.The 12 eyes were treated with Ahmed glaucoma valve implant surgery,and the patients were followed up for(4.7±1.2) months(ranging 3-6 months).Results The mean intraocular pressure decreased from(40.5±10.2) mmHg(1 mmHg=0.133 kPa) before the implant surgery(ranging 30.5-50.7 mmHg) to(13.5±4.3) mmHg after the surgery(ranging 8.0-21.0 mmHg).The successful rate of the implant surgery was 100%.Two eyes had obstruction of drainage tube 2 weeks after the surgery and were recanalized after rinsing,with no other complications.Conclusion Ahmed glaucoma valve implant is effective and safe for glaucoma after vitrectomy.(Shanghai Med J,2010,33: 191-193)
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the efficacy and safety of Ahmed glaucoma valve implantation for glaucoma following vitrectomy surgery.Methods Twelve patients(12 eyes) who had been diagnosed with glaucoma after vitrectomy and phacoemulsification surgery due to retina detachment were selected in this study.The 12 eyes were treated with Ahmed glaucoma valve implant surgery,and the patients were followed up for(4.7±1.2) months(ranging 3-6 months).Results The mean intraocular pressure decreased from(40.5±10.2) mmHg(1 mmHg=0.133 kPa) before the implant surgery(ranging 30.5-50.7 mmHg) to(13.5±4.3) mmHg after the surgery(ranging 8.0-21.0 mmHg).The successful rate of the implant surgery was 100%.Two eyes had obstruction of drainage tube 2 weeks after the surgery and were recanalized after rinsing,with no other complications.Conclusion Ahmed glaucoma valve implant is effective and safe for glaucoma after vitrectomy.(Shanghai Med J,2010,33: 191-193)
Key concepts: Medicine, Glaucoma valve, Vitrectomy, Glaucoma, Implant, Intraocular pressure, Ophthalmology, Phacoemulsification