[The Ahmed glaucoma valve implantation for refractory glaucoma].
Xiaosheng Yang, Xiaodong Zheng, Xueliang Jeff Pan, W Wang
Abstract
Xiaosheng Yang, Xiaodong Zheng, Xueliang Jeff Pan, W Wang
Abstract
OBJECTIVE: To evaluate the efficacy of the Ahmed Glaucoma Valve implant in the treatment of refractory glaucoma. METHODS: 28 cases(29 eyes) of refractory glacucoma were treated by the Ahmed glaucoma Valve implant, including 10 cases (10 eyes) of neovascula glaucoma, 5 cases (6 eyes) of juvenile glaucoma and 13 cases (13 eyes) of other causes glaucoma. RESULTS: Post-operative follow-up time was 3-12 months. The intraocular pressure (IOP) was lowered from preoperative 40.9 +/- 7.32 mmHg (1 mmHg = 0.133 kPa) to postoperative 20.63 +/- 2.75 mmHg in Neovascular glaucoma; from preoperative 41 +/- 5.66 to postoperative 18.00 +/- 2.12 mmHg in glaucoma after IOL implant combined with vitrectomy operation; from preoperative 33.65 +/- 5.28 to postoperative 16.45 +/- 1.48 mmHg in juvenile glaucoma; from preoperative 31.43 +/- 4.13 to postoperative 18.13 +/- 1.25 mmHg in the failure conventional filtering surgery of glaucoma. The postoperative complicatons were flat anterior chamber, hyphema, anterior iritis and so on. CONCLUSION: The Ahmed glaucoma valve implant is a useful method in lowing IOP of refractory glaucoma.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To evaluate the efficacy of the Ahmed Glaucoma Valve implant in the treatment of refractory glaucoma. METHODS: 28 cases(29 eyes) of refractory glacucoma were treated by the Ahmed glaucoma Valve implant, including 10 cases (10 eyes) of neovascula glaucoma, 5 cases (6 eyes) of juvenile glaucoma and 13 cases (13 eyes) of other causes glaucoma. RESULTS: Post-operative follow-up time was 3-12 months. The intraocular pressure (IOP) was lowered from preoperative 40.9 +/- 7.32 mmHg (1 mmHg = 0.133 kPa) to postoperative 20.63 +/- 2.75 mmHg in Neovascular glaucoma; from preoperative 41 +/- 5.66 to postoperative 18.00 +/- 2.12 mmHg in glaucoma after IOL implant combined with vitrectomy operation; from preoperative 33.65 +/- 5.28 to postoperative 16.45 +/- 1.48 mmHg in juvenile glaucoma; from preoperative 31.43 +/- 4.13 to postoperative 18.13 +/- 1.25 mmHg in the failure conventional filtering surgery of glaucoma. The postoperative complicatons were flat anterior chamber, hyphema, anterior iritis and so on. CONCLUSION: The Ahmed glaucoma valve implant is a useful method in lowing IOP of refractory glaucoma.
Key concepts: Medicine, Glaucoma, Glaucoma valve, Refractory (planetary science), Implant, Intraocular pressure, Ophthalmology, Hyphema