2021Nigerian Journal of Clinical PracticeOpen access

Cyclic Fatigue Resistance and Shaping Ability of Heat-Treated Nickel-Titanium Instruments after Repeated Use

SG Kamali, Dilek Türkaydın

Open full text 9 citations

Abstract

AIMS: To evaluate the effect of multiple-use and sterilization on cyclic fatigue and shaping ability of heat-treated nickel-titanium (NiTi) rotary instruments. METHODS: A total of 120 acrylic blocks with S-shaped canals were photographed and prepared by HyFlex CM, ProTaper Next, and Twisted File. Ten new sets of each rotary instruments were used for four times. The autoclaving process was repeated after each use. Pre- and post instrumentation images were superimposed. The amount of resin removal and canal transportation by each system was measured in eleven different points. Instruments were subsequently subjected to a cyclic fatigue test in a double-curved artificial canal. The means and standard deviations of the number of cycles to failure (NCF) were calculated and statistically analyzed (P < 0.05). RESULTS: No fractures occurred during the shaping of the simulated canals. The ProTaper Next removed the greatest amount of resin, whereas the Twisted File had the lowest values at all levels. Repeated clinical use and sterilization resulted in a decrease in the resin removal at most levels in Twisted File and ProTaper Next. In terms of canal transportation, an increase in a limited number of levels was detected after repeated use of all rotary files. Twisted File had the greatest cyclic fatigue resistance, followed by HyFlex CM and ProTaper Next (P < 0.05). CONCLUSIONS: The effects of repeated use and autoclaving on the cyclic fatigue resistance of HyFlex CM, ProTaper Next, and Twisted File were not significant. Canal transportation increased mostly in the apical region. The amount of resin removal decreased as the number of use increased for ProTaper Next and Twisted File instruments.

About this research paper

What this paper is about

AIMS: To evaluate the effect of multiple-use and sterilization on cyclic fatigue and shaping ability of heat-treated nickel-titanium (NiTi) rotary instruments. METHODS: A total of 120 acrylic blocks with S-shaped canals were photographed and prepared by HyFlex CM, ProTaper Next, and Twisted File. Ten new sets of each rotary instruments were used for four times. The autoclaving process was repeated after each use. Pre- and post instrumentation images were superimposed. The amount of resin removal and canal transportation by each system was measured in eleven different points. Instruments were subsequently subjected to a cyclic fatigue test in a double-curved artificial canal. The means and standard deviations of the number of cycles to failure (NCF) were calculated and statistically analyzed (P < 0.05). RESULTS: No fractures occurred during the shaping of the simulated canals. The ProTaper Next removed the greatest amount of resin, whereas the Twisted File had the lowest values at all levels. Repeated clinical use and sterilization resulted in a decrease in the resin removal at most levels in Twisted File and ProTaper Next. In terms of canal transportation, an increase in a limited number of levels was detected after repeated use of all rotary files. Twisted File had the greatest cyclic fatigue resistance, followed by HyFlex CM and ProTaper Next (P < 0.05). CONCLUSIONS: The effects of repeated use and autoclaving on the cyclic fatigue resistance of HyFlex CM, ProTaper Next, and Twisted File were not significant. Canal transportation increased mostly in the apical region. The amount of resin removal decreased as the number of use increased for ProTaper Next and Twisted File instruments.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIMS: To evaluate the effect of multiple-use and sterilization on cyclic fatigue and shaping ability of heat-treated nickel-titanium (NiTi) rotary instruments. METHODS: A total of 120 acrylic blocks with S-shaped canals were photographed and prepared by HyFlex CM, ProTaper Next, and Twisted File. Ten new sets of each rotary instruments were used for four times. The autoclaving process was repeated after each use. Pre- and post instrumentation images were superimposed. The amount of resin removal and canal transportation by each system was measured in eleven different points. Instruments were subsequently subjected to a cyclic fatigue test in a double-curved artificial canal. The means and standard deviations of the number of cycles to failure (NCF) were calculated and statistically analyzed (P < 0.05). RESULTS: No fractures occurred during the shaping of the simulated canals. The ProTaper Next removed the greatest amount of resin, whereas the Twisted File had the lowest values at all levels. Repeated clinical use and sterilization resulted in a decrease in the resin removal at most levels in Twisted File and ProTaper Next. In terms of canal transportation, an increase in a limited number of levels was detected after repeated use of all rotary files. Twisted File had the greatest cyclic fatigue resistance, followed by HyFlex CM and ProTaper Next (P < 0.05). CONCLUSIONS: The effects of repeated use and autoclaving on the cyclic fatigue resistance of HyFlex CM, ProTaper Next, and Twisted File were not significant. Canal transportation increased mostly in the apical region. The amount of resin removal decreased as the number of use increased for ProTaper Next and Twisted File instruments.

Key concepts: Nickel titanium, Cyclic stress, Dental instruments, Medicine, Dentistry, Sterilization (economics), Orthodontics, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
Cyclic Fatigue Resistance and Shaping Ability of Heat-Treated Nickel-Titanium Instruments after Repeated Use — Research Paper | ScholarLens