2023Tikrit Journal for Dental SciencesOpen access

Influence of Anatomical Root Factors on Cyclic Fatigue Resistance of Heat Treated NiTi Instrument: A Review

Ahmed A. Malik, Iman M. Al-Zaka

Open full text 0 citations

Abstract

Endodontic treatments have been improved over the last decade by the use of nickel titanium (NiTi) alloys. NiTi instrument had shape memory and superelastic properties which made the instrument more flexible, so the treatment quality was enhanced by eliminating the procedural errors. Although the numerous benefits of the NiTi instruments, the fracture was the most frequent failure that may be happened during its use due to flexural (cyclic) or torsional fatigue. Various thermo-mechanical heat treatments have been applied to NiTi instruments to improve fracture resistance and clinical performance. Several parameters influenced the fatigue resistance of NiTi files, and the most important factor that affected the likelihood of NiTi instrument fatigue was the root canal shape. Data collected of 100 papers from the Goggle scholar and Scien ceDirect database. After excluding 60 unrelated papers, thi s review of 40 included related studies aims to evaluate an overview of the anatomical root-related factors affecting t he cyclic fatigue of heat-treated NiTi instruments. Concl uded that the separation rates of file increased when the radius of curvature decreases and when the angle of curvature increased. Canals with the double curvatures increase the risk of cyclic fatigue. Also, the resistance to cyclic fatigue of NiTi files was affected by the canal curvature posit ion, with a short failure life coronally. So even in the improve ment of wire metallurgy and designs of instrument, the anatomy of canal still impact on the cyclic fatigue and should be considered during preparation especially with th e new concept of minimally invasive endodontic treatmen t.

Open-access reader

About this research paper

What this paper is about

Endodontic treatments have been improved over the last decade by the use of nickel titanium (NiTi) alloys. NiTi instrument had shape memory and superelastic properties which made the instrument more flexible, so the treatment quality was enhanced by eliminating the procedural errors. Although the numerous benefits of the NiTi instruments, the fracture was the most frequent failure that may be happened during its use due to flexural (cyclic) or torsional fatigue. Various thermo-mechanical heat treatments have been applied to NiTi instruments to improve fracture resistance and clinical performance. Several parameters influenced the fatigue resistance of NiTi files, and the most important factor that affected the likelihood of NiTi instrument fatigue was the root canal shape. Data collected of 100 papers from the Goggle scholar and Scien ceDirect database. After excluding 60 unrelated papers, thi s review of 40 included related studies aims to evaluate an overview of the anatomical root-related factors affecting t he cyclic fatigue of heat-treated NiTi instruments. Concl uded that the separation rates of file increased when the radius of curvature decreases and when the angle of curvature increased. Canals with the double curvatures increase the risk of cyclic fatigue. Also, the resistance to cyclic fatigue of NiTi files was affected by the canal curvature posit ion, with a short failure life coronally. So even in the improve ment of wire metallurgy and designs of instrument, the anatomy of canal still impact on the cyclic fatigue and should be considered during preparation especially with th e new concept of minimally invasive endodontic treatmen t.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Endodontic treatments have been improved over the last decade by the use of nickel titanium (NiTi) alloys. NiTi instrument had shape memory and superelastic properties which made the instrument more flexible, so the treatment quality was enhanced by eliminating the procedural errors. Although the numerous benefits of the NiTi instruments, the fracture was the most frequent failure that may be happened during its use due to flexural (cyclic) or torsional fatigue. Various thermo-mechanical heat treatments have been applied to NiTi instruments to improve fracture resistance and clinical performance. Several parameters influenced the fatigue resistance of NiTi files, and the most important factor that affected the likelihood of NiTi instrument fatigue was the root canal shape. Data collected of 100 papers from the Goggle scholar and Scien ceDirect database. After excluding 60 unrelated papers, thi s review of 40 included related studies aims to evaluate an overview of the anatomical root-related factors affecting t he cyclic fatigue of heat-treated NiTi instruments. Concl uded that the separation rates of file increased when the radius of curvature decreases and when the angle of curvature increased. Canals with the double curvatures increase the risk of cyclic fatigue. Also, the resistance to cyclic fatigue of NiTi files was affected by the canal curvature posit ion, with a short failure life coronally. So even in the improve ment of wire metallurgy and designs of instrument, the anatomy of canal still impact on the cyclic fatigue and should be considered during preparation especially with th e new concept of minimally invasive endodontic treatmen t.

Key concepts: Nickel titanium, Cyclic stress, Root canal, Fracture (geology), Radius of curvature, Fatigue testing, Materials science, Dental instruments

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of Anatomical Root Factors on Cyclic Fatigue Resistance of Heat Treated NiTi Instrument: A Review — Research Paper | ScholarLens