2021Microscopy and MicroanalysisRequires access

Integrative Atom Probe Tomography Using Scanning Transmission Electron Microscopy-Centric Atom Placement as a Step Toward Atomic-Scale Tomography

Anna V. Ceguerra, Andrew Breen, Julie M. Cairney, Simon P. Ringer, Brian P. Gorman

Open publisher page 10 citations

Abstract

Current reconstruction methodologies for atom probe tomography (APT) contain serious geometric artifacts that are difficult to address due to their reliance on empirical factors to generate a reconstructed volume. To overcome this limitation, a reconstruction technique is demonstrated where the analyzed volume is instead defined by the specimen geometry and crystal structure as determined by transmission electron microscopy (TEM) and diffraction acquired before and after APT analysis. APT data are reconstructed using a bottom-up approach, where the post-APT TEM image is used to define the substrate upon which APT detection events are placed. Transmission electron diffraction enables the quantification of the relationship between atomic positions and the evaporated specimen volume. Using an example dataset of ZnMgO:Ga grown epitaxially on c-plane sapphire, a volume is reconstructed that has the correct geometry and atomic spacings in 3D. APT data are thus reconstructed in 3D without using empirical parameters for the reverse projection reconstruction algorithm.

About this research paper

What this paper is about

Current reconstruction methodologies for atom probe tomography (APT) contain serious geometric artifacts that are difficult to address due to their reliance on empirical factors to generate a reconstructed volume. To overcome this limitation, a reconstruction technique is demonstrated where the analyzed volume is instead defined by the specimen geometry and crystal structure as determined by transmission electron microscopy (TEM) and diffraction acquired before and after APT analysis. APT data are reconstructed using a bottom-up approach, where the post-APT TEM image is used to define the substrate upon which APT detection events are placed. Transmission electron diffraction enables the quantification of the relationship between atomic positions and the evaporated specimen volume. Using an example dataset of ZnMgO:Ga grown epitaxially on c-plane sapphire, a volume is reconstructed that has the correct geometry and atomic spacings in 3D. APT data are thus reconstructed in 3D without using empirical parameters for the reverse projection reconstruction algorithm.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Current reconstruction methodologies for atom probe tomography (APT) contain serious geometric artifacts that are difficult to address due to their reliance on empirical factors to generate a reconstructed volume. To overcome this limitation, a reconstruction technique is demonstrated where the analyzed volume is instead defined by the specimen geometry and crystal structure as determined by transmission electron microscopy (TEM) and diffraction acquired before and after APT analysis. APT data are reconstructed using a bottom-up approach, where the post-APT TEM image is used to define the substrate upon which APT detection events are placed. Transmission electron diffraction enables the quantification of the relationship between atomic positions and the evaporated specimen volume. Using an example dataset of ZnMgO:Ga grown epitaxially on c-plane sapphire, a volume is reconstructed that has the correct geometry and atomic spacings in 3D. APT data are thus reconstructed in 3D without using empirical parameters for the reverse projection reconstruction algorithm.

Key concepts: Atom probe, Electron tomography, Atomic units, Tomography, Scanning transmission electron microscopy, Atom (system on chip), Materials science, Transmission electron microscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Integrative Atom Probe Tomography Using Scanning Transmission Electron Microscopy-Centric Atom Placement as a Step Toward Atomic-Scale Tomography — Research Paper | ScholarLens