Cloud Point Extraction for Pre-Concentration and Spectrophotometric Determination of Trace Amounts of Silver Ions
Azhar A. Ghali
Abstract
Open-access reader
Azhar A. Ghali
Abstract
Open-access reader
During the last years, the cloud point extraction was applied for determination, separation, and enrichment of the elements. The current study used cloud point extraction (CPE) for the extraction of Ag(I) ions pre-concentration from watery solutions by a non-ionic surfactant (Triton X-114) and chelating agent a 6-(4-bromo-phenylazo)m-anisidine[6-(4-BrPAA)], then estimation by using the spectrophotometry at 514 nm. Several condition effects on the efficiency of the cloud-point extraction included Triton X-114 concentration, [6-(4-BrPAA)] concentration, pH, time, and incubation temperature. The silver reacts with [6-(4-BrPAA)] to produce complex at a ratio of one to one. 0.009 to 1.5 μg mL-1 is the range of linearity. The detection limit and quantification of Ag(I) ion were 0.0054 and 0.0182 μg mL-1, respectively. The interference of the cations was examined. The cloud-point extraction was used for the evaluation of silver concentration in the water specimen.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
During the last years, the cloud point extraction was applied for determination, separation, and enrichment of the elements. The current study used cloud point extraction (CPE) for the extraction of Ag(I) ions pre-concentration from watery solutions by a non-ionic surfactant (Triton X-114) and chelating agent a 6-(4-bromo-phenylazo)m-anisidine[6-(4-BrPAA)], then estimation by using the spectrophotometry at 514 nm. Several condition effects on the efficiency of the cloud-point extraction included Triton X-114 concentration, [6-(4-BrPAA)] concentration, pH, time, and incubation temperature. The silver reacts with [6-(4-BrPAA)] to produce complex at a ratio of one to one. 0.009 to 1.5 μg mL-1 is the range of linearity. The detection limit and quantification of Ag(I) ion were 0.0054 and 0.0182 μg mL-1, respectively. The interference of the cations was examined. The cloud-point extraction was used for the evaluation of silver concentration in the water specimen.
Key concepts: Cloud point, Extraction (chemistry), Detection limit, Trace Amounts, Chemistry, Spectrophotometry, Chromatography, Analytical Chemistry (journal)