Double-strand breaks measured along a 160 MeV proton Bragg curve using a novel FIESTA-DNA probe in a cell-free environment

Kristen McConnell, Chang Chang, Annelise Giebeler, Lawrence Liu, Lingyan Zhu Qu, Vitali Moiseenko

Open publisher page 2 citations

Abstract

Abstract Proton radiotherapy treatment planning systems use a constant relative biological effectiveness (RBE) = 1.1 to convert proton absorbed dose into biologically equivalent high-energy photon dose. This method ignores linear energy transfer (LET) distributions, and RBE is known to change as a function of LET. Variable RBE approaches have been proposed for proton planning optimization. Experimental validation of models underlying these approaches is a pre-requisite for their clinical implementation. This validation has to probe every level in the evolution of radiation-induced biological damage leading to cell death, starting from DNA double-strand breaks (DSB). Using a novel FIESTA-DNA probe, we measured the probability of double-strand break ( P DSB ) along a 160 MeV proton Bragg curve at two dose levels (30 and 60 Gy (RBE)) and compared it to measurements in a 6 MV photon beam. A machined setup that held an Advanced Markus parallel plate chamber for proton dose verification alongside the probes was fabricated. Each sample set consisted of five 10 μ l probes suspended inside plastic microcapillary tubes. These were irradiated with protons to 30 Gy (RBE) at depths of 5–17.5 cm and 60 Gy (RBE) at depths of 10–17.2 cm with 1 mm resolution around Bragg peak. Sample sets were also irradiated using 6MV photons to 20, 40, 60, and 80 Gy. For the 30 Gy (RBE) measurements, increases in P DSB /Gy were observed at 17.0 cm followed by decreases at larger depth. For the 60 Gy (RBE) measurements, no increase in P DSB /Gy was observed, but there was a decrease after 17.0 cm. Dose-response for P DSB between 30 and 60 Gy (RBE) showed less than doubling of P DSB when dose was doubled. Proton RBE effect from DSB, RBE P,DSB , was <1 except at the Bragg peak. The experiment showed that the novel probe can be used to perform DNA DSB measurements in a proton beam. To establish relevance to clinical environment, further investigation of the probe’s chemical scavenging needs to be performed.

About this research paper

What this paper is about

Abstract Proton radiotherapy treatment planning systems use a constant relative biological effectiveness (RBE) = 1.1 to convert proton absorbed dose into biologically equivalent high-energy photon dose. This method ignores linear energy transfer (LET) distributions, and RBE is known to change as a function of LET. Variable RBE approaches have been proposed for proton planning optimization. Experimental validation of models underlying these approaches is a pre-requisite for their clinical implementation. This validation has to probe every level in the evolution of radiation-induced biological damage leading to cell death, starting from DNA double-strand breaks (DSB). Using a novel FIESTA-DNA probe, we measured the probability of double-strand break ( P DSB ) along a 160 MeV proton Bragg curve at two dose levels (30 and 60 Gy (RBE)) and compared it to measurements in a 6 MV photon beam. A machined setup that held an Advanced Markus parallel plate chamber for proton dose verification alongside the probes was fabricated. Each sample set consisted of five 10 μ l probes suspended inside plastic microcapillary tubes. These were irradiated with protons to 30 Gy (RBE) at depths of 5–17.5 cm and 60 Gy (RBE) at depths of 10–17.2 cm with 1 mm resolution around Bragg peak. Sample sets were also irradiated using 6MV photons to 20, 40, 60, and 80 Gy. For the 30 Gy (RBE) measurements, increases in P DSB /Gy were observed at 17.0 cm followed by decreases at larger depth. For the 60 Gy (RBE) measurements, no increase in P DSB /Gy was observed, but there was a decrease after 17.0 cm. Dose-response for P DSB between 30 and 60 Gy (RBE) showed less than doubling of P DSB when dose was doubled. Proton RBE effect from DSB, RBE P,DSB , was <1 except at the Bragg peak. The experiment showed that the novel probe can be used to perform DNA DSB measurements in a proton beam. To establish relevance to clinical environment, further investigation of the probe’s chemical scavenging needs to be performed.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Proton radiotherapy treatment planning systems use a constant relative biological effectiveness (RBE) = 1.1 to convert proton absorbed dose into biologically equivalent high-energy photon dose. This method ignores linear energy transfer (LET) distributions, and RBE is known to change as a function of LET. Variable RBE approaches have been proposed for proton planning optimization. Experimental validation of models underlying these approaches is a pre-requisite for their clinical implementation. This validation has to probe every level in the evolution of radiation-induced biological damage leading to cell death, starting from DNA double-strand breaks (DSB). Using a novel FIESTA-DNA probe, we measured the probability of double-strand break ( P DSB ) along a 160 MeV proton Bragg curve at two dose levels (30 and 60 Gy (RBE)) and compared it to measurements in a 6 MV photon beam. A machined setup that held an Advanced Markus parallel plate chamber for proton dose verification alongside the probes was fabricated. Each sample set consisted of five 10 μ l probes suspended inside plastic microcapillary tubes. These were irradiated with protons to 30 Gy (RBE) at depths of 5–17.5 cm and 60 Gy (RBE) at depths of 10–17.2 cm with 1 mm resolution around Bragg peak. Sample sets were also irradiated using 6MV photons to 20, 40, 60, and 80 Gy. For the 30 Gy (RBE) measurements, increases in P DSB /Gy were observed at 17.0 cm followed by decreases at larger depth. For the 60 Gy (RBE) measurements, no increase in P DSB /Gy was observed, but there was a decrease after 17.0 cm. Dose-response for P DSB between 30 and 60 Gy (RBE) showed less than doubling of P DSB when dose was doubled. Proton RBE effect from DSB, RBE P,DSB , was <1 except at the Bragg peak. The experiment showed that the novel probe can be used to perform DNA DSB measurements in a proton beam. To establish relevance to clinical environment, further investigation of the probe’s chemical scavenging needs to be performed.

Key concepts: Bragg peak, Relative biological effectiveness, Linear energy transfer, Proton, Proton therapy, Irradiation, Double strand, Absorbed dose