Point-of-Care Testing Effectiveness on Blood Donor Hemoglobin Testing

Kayleigh Grech, Vanessa Zammit

Open publisher page 2 citations

Abstract

BACKGROUND: Hemoglobin (Hb) evaluation by point-of-care testing (POCT) identifies borderline or anaemic asymptomatic blood donors. Although quality control checks confirm that this device is fit for use, it is still not clear whether the analyser is performing effectively. A protocol comparing the POCT EKF Diagnostics with the Sysmex XN-550 automated cell counter (ACC) has been designed. METHODS: Various scenarios of Hb measurements from the ACC and the POCT device are compared using the Spearman correlation and Intraclass correlation. The Bland-Altman method was used to analyse the level of agreement between the two devices. RESULTS: Correlation between the two devices was best observed in the venous vs venous blood scenario. CONCLUSION: The POCT device overestimates the Hb levels in capillary blood, meaning that Hb requirements should be adjusted and when feasible testing repeated on venous blood using an ACC. Furthermore, it is suggested thar each Facility determine their own Hb threshold.

About this research paper

What this paper is about

BACKGROUND: Hemoglobin (Hb) evaluation by point-of-care testing (POCT) identifies borderline or anaemic asymptomatic blood donors. Although quality control checks confirm that this device is fit for use, it is still not clear whether the analyser is performing effectively. A protocol comparing the POCT EKF Diagnostics with the Sysmex XN-550 automated cell counter (ACC) has been designed. METHODS: Various scenarios of Hb measurements from the ACC and the POCT device are compared using the Spearman correlation and Intraclass correlation. The Bland-Altman method was used to analyse the level of agreement between the two devices. RESULTS: Correlation between the two devices was best observed in the venous vs venous blood scenario. CONCLUSION: The POCT device overestimates the Hb levels in capillary blood, meaning that Hb requirements should be adjusted and when feasible testing repeated on venous blood using an ACC. Furthermore, it is suggested thar each Facility determine their own Hb threshold.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Hemoglobin (Hb) evaluation by point-of-care testing (POCT) identifies borderline or anaemic asymptomatic blood donors. Although quality control checks confirm that this device is fit for use, it is still not clear whether the analyser is performing effectively. A protocol comparing the POCT EKF Diagnostics with the Sysmex XN-550 automated cell counter (ACC) has been designed. METHODS: Various scenarios of Hb measurements from the ACC and the POCT device are compared using the Spearman correlation and Intraclass correlation. The Bland-Altman method was used to analyse the level of agreement between the two devices. RESULTS: Correlation between the two devices was best observed in the venous vs venous blood scenario. CONCLUSION: The POCT device overestimates the Hb levels in capillary blood, meaning that Hb requirements should be adjusted and when feasible testing repeated on venous blood using an ACC. Furthermore, it is suggested thar each Facility determine their own Hb threshold.

Key concepts: Point-of-care testing, Medicine, Point of care, Venous blood, Hemoglobin, Intraclass correlation, Asymptomatic, Bland–Altman plot

Related papers

Back to paper searchBrowse research topicsOriginal source
Point-of-Care Testing Effectiveness on Blood Donor Hemoglobin Testing — Research Paper | ScholarLens