2020•Jurnal Nasional Teknik ElektroOpen access

Harmonics of CF and LED lamps - Maximum Penetration Perspective on Power Quality in Distribution Systems

Francis Boafo Effah, P. D. Gasu, Philip Yaw Okyere, Amevi Acakpovi

Open full text 1 citations

Abstract

Global energy saving efforts have led to replacement of incandescent lamps with energy-efficient ones like light-emitting diode (LED) and compact fluorescent lamps (CFLs). These lamps, being non-linear loads, have the potential of injecting harmonics into distribution networks. In this paper, harmonics injection of common CFL and LED lamps at a facility point of common coupling is investigated. To gain insight into large scale penetration effects on power quality, field measurement results of popular lamps used in Ghana were replicated in MATLAB/Simulink through simulation. The field results showed that LED lamps exhibit more harmonics compared to CFL lamps. Maximum possible loading on a 100-kVA, 11kV/0.433kV distribution transformer was found to be 24.02% for CFL, 27.14% for LED, and 40.91% for a mixture of the two lamps, respectively, in order not to violate IEEE 519-2014 standard. The influence of other common loads such as ceiling fans on the lamps’ harmonics were assessed in the field measurement. The use of ceiling fans with the lamps in the facility reduced the harmonics and improved the power factor of the facility. Since the lamps exist in residential and commercial facilities with other loads, more penetration of energy-saving lamps in the distribution system will have little influence on power quality. Keywords : Compact fluorescent lamps, light emitting diodes, maximum power loading, total harmonic distortion, point of common coupling

Open-access reader

About this research paper

What this paper is about

Global energy saving efforts have led to replacement of incandescent lamps with energy-efficient ones like light-emitting diode (LED) and compact fluorescent lamps (CFLs). These lamps, being non-linear loads, have the potential of injecting harmonics into distribution networks. In this paper, harmonics injection of common CFL and LED lamps at a facility point of common coupling is investigated. To gain insight into large scale penetration effects on power quality, field measurement results of popular lamps used in Ghana were replicated in MATLAB/Simulink through simulation. The field results showed that LED lamps exhibit more harmonics compared to CFL lamps. Maximum possible loading on a 100-kVA, 11kV/0.433kV distribution transformer was found to be 24.02% for CFL, 27.14% for LED, and 40.91% for a mixture of the two lamps, respectively, in order not to violate IEEE 519-2014 standard. The influence of other common loads such as ceiling fans on the lamps’ harmonics were assessed in the field measurement. The use of ceiling fans with the lamps in the facility reduced the harmonics and improved the power factor of the facility. Since the lamps exist in residential and commercial facilities with other loads, more penetration of energy-saving lamps in the distribution system will have little influence on power quality. Keywords : Compact fluorescent lamps, light emitting diodes, maximum power loading, total harmonic distortion, point of common coupling

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Global energy saving efforts have led to replacement of incandescent lamps with energy-efficient ones like light-emitting diode (LED) and compact fluorescent lamps (CFLs). These lamps, being non-linear loads, have the potential of injecting harmonics into distribution networks. In this paper, harmonics injection of common CFL and LED lamps at a facility point of common coupling is investigated. To gain insight into large scale penetration effects on power quality, field measurement results of popular lamps used in Ghana were replicated in MATLAB/Simulink through simulation. The field results showed that LED lamps exhibit more harmonics compared to CFL lamps. Maximum possible loading on a 100-kVA, 11kV/0.433kV distribution transformer was found to be 24.02% for CFL, 27.14% for LED, and 40.91% for a mixture of the two lamps, respectively, in order not to violate IEEE 519-2014 standard. The influence of other common loads such as ceiling fans on the lamps’ harmonics were assessed in the field measurement. The use of ceiling fans with the lamps in the facility reduced the harmonics and improved the power factor of the facility. Since the lamps exist in residential and commercial facilities with other loads, more penetration of energy-saving lamps in the distribution system will have little influence on power quality. Keywords : Compact fluorescent lamps, light emitting diodes, maximum power loading, total harmonic distortion, point of common coupling

Key concepts: Harmonics, Incandescent light bulb, LED lamp, Total harmonic distortion, Electrical engineering, Automotive engineering, Sodium-vapor lamp, Transformer

Related papers

Back to paper searchBrowse research topicsOriginal source
Harmonics of CF and LED lamps - Maximum Penetration Perspective on Power Quality in Distribution Systems — Research Paper | ScholarLens