2017Unpublished venueRequires access

Effect of lamp technologies on the power quality of electrical distribution network

A.S.O. Ogunjuyigbe, T.R. Ayodele, V. E. Idika, Olorunfemi Ojo

Open publisher page 19 citations

Abstract

The increased use of non-linear loads such as lighting technologies (bulbs) has led to power quality variation of distribution networks. In recent times, different lighting technologies are finding their ways into the market. As such, it is paramount to evaluate the performance characteristics of these lighting technologies and the possible effects they might have on the power network. In this paper, three lamp technologies i.e. Light Emitting Diode (LED) lamps, Incandescent Lamps (IC) and Compact-fluorescent lamps (CFL) are analysed to check the impact of their usage on the power quality of a distribution system through a laboratory experiment. The result revealed that the LED lamps offer the highest savings in energy consumption compared to CFLs and ICs. However, they (LED lamps) constitute the highest harmonic pollution in comparison to the other lamps. From the study, it seems no single lamp is preferable when considering energy saving and power quality at the same time. The choice would have to depend on which of metrics is under consideration. In cases where power quality issues is of prime importance, traditional incandescent lamps are the most preferred, on the other hand when energy conservation is the focus, the LED lamps are the most favourable. CFLs offer moderate energy savings and produce fewer harmonics compared to the LED.

About this research paper

What this paper is about

The increased use of non-linear loads such as lighting technologies (bulbs) has led to power quality variation of distribution networks. In recent times, different lighting technologies are finding their ways into the market. As such, it is paramount to evaluate the performance characteristics of these lighting technologies and the possible effects they might have on the power network. In this paper, three lamp technologies i.e. Light Emitting Diode (LED) lamps, Incandescent Lamps (IC) and Compact-fluorescent lamps (CFL) are analysed to check the impact of their usage on the power quality of a distribution system through a laboratory experiment. The result revealed that the LED lamps offer the highest savings in energy consumption compared to CFLs and ICs. However, they (LED lamps) constitute the highest harmonic pollution in comparison to the other lamps. From the study, it seems no single lamp is preferable when considering energy saving and power quality at the same time. The choice would have to depend on which of metrics is under consideration. In cases where power quality issues is of prime importance, traditional incandescent lamps are the most preferred, on the other hand when energy conservation is the focus, the LED lamps are the most favourable. CFLs offer moderate energy savings and produce fewer harmonics compared to the LED.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The increased use of non-linear loads such as lighting technologies (bulbs) has led to power quality variation of distribution networks. In recent times, different lighting technologies are finding their ways into the market. As such, it is paramount to evaluate the performance characteristics of these lighting technologies and the possible effects they might have on the power network. In this paper, three lamp technologies i.e. Light Emitting Diode (LED) lamps, Incandescent Lamps (IC) and Compact-fluorescent lamps (CFL) are analysed to check the impact of their usage on the power quality of a distribution system through a laboratory experiment. The result revealed that the LED lamps offer the highest savings in energy consumption compared to CFLs and ICs. However, they (LED lamps) constitute the highest harmonic pollution in comparison to the other lamps. From the study, it seems no single lamp is preferable when considering energy saving and power quality at the same time. The choice would have to depend on which of metrics is under consideration. In cases where power quality issues is of prime importance, traditional incandescent lamps are the most preferred, on the other hand when energy conservation is the focus, the LED lamps are the most favourable. CFLs offer moderate energy savings and produce fewer harmonics compared to the LED.

Key concepts: Incandescent light bulb, LED lamp, Harmonics, Fluorescent lamp, Electric light, Sodium-vapor lamp, Energy conservation, Automotive engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of lamp technologies on the power quality of electrical distribution network — Research Paper | ScholarLens