2020EnergiesOpen access

Study on the Performance of Multiple Sources and Multiple Uses Heat Pump System in Three Different Cities

Hongkyo Kim, Yujin Nam, Sangmu Bae, Soolyeon Cho

Open full text 11 citations

Abstract

Various efforts have been made worldwide to reduce energy use for heating, ventilation, and air-conditioning (HVAC) systems and lower carbon dioxide (CO2) emissions. Research and development are essential to ensuring the efficient use of renewable energy systems. This study proposes a multiple sources and multiple uses heat pump (MMHP) system that can efficiently respond to heating, cooling, and domestic hot water (DHW) loads using multiple natural heat sources. The MMHP system uses ground and air heat as its primary heat sources and solar heat for heat storage operations and ground temperature recovery. For the efficient use of each heat source, it also determines the heat source required for operation by comparing the heat source temperatures in the same time zone. A model for predicting the heat source temperatures, electricity use, and coefficient of performance (COP) was constructed through simulation. To analyze the efficiency of the proposed system by comparing the existing air source heat pump with ground source heat pump systems, a performance analysis was conducted by setting regional and system configurations as case conditions. The results demonstrate that the electricity use of the MMHP system was 13–19% and 1–3% lower than those of air source heat pump (ASHP) and ground source (GSHP) systems, respectively. In addition, the MMHP system was the most favorable in regions with a low heating load.

Open-access reader

About this research paper

What this paper is about

Various efforts have been made worldwide to reduce energy use for heating, ventilation, and air-conditioning (HVAC) systems and lower carbon dioxide (CO2) emissions. Research and development are essential to ensuring the efficient use of renewable energy systems. This study proposes a multiple sources and multiple uses heat pump (MMHP) system that can efficiently respond to heating, cooling, and domestic hot water (DHW) loads using multiple natural heat sources. The MMHP system uses ground and air heat as its primary heat sources and solar heat for heat storage operations and ground temperature recovery. For the efficient use of each heat source, it also determines the heat source required for operation by comparing the heat source temperatures in the same time zone. A model for predicting the heat source temperatures, electricity use, and coefficient of performance (COP) was constructed through simulation. To analyze the efficiency of the proposed system by comparing the existing air source heat pump with ground source heat pump systems, a performance analysis was conducted by setting regional and system configurations as case conditions. The results demonstrate that the electricity use of the MMHP system was 13–19% and 1–3% lower than those of air source heat pump (ASHP) and ground source (GSHP) systems, respectively. In addition, the MMHP system was the most favorable in regions with a low heating load.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Various efforts have been made worldwide to reduce energy use for heating, ventilation, and air-conditioning (HVAC) systems and lower carbon dioxide (CO2) emissions. Research and development are essential to ensuring the efficient use of renewable energy systems. This study proposes a multiple sources and multiple uses heat pump (MMHP) system that can efficiently respond to heating, cooling, and domestic hot water (DHW) loads using multiple natural heat sources. The MMHP system uses ground and air heat as its primary heat sources and solar heat for heat storage operations and ground temperature recovery. For the efficient use of each heat source, it also determines the heat source required for operation by comparing the heat source temperatures in the same time zone. A model for predicting the heat source temperatures, electricity use, and coefficient of performance (COP) was constructed through simulation. To analyze the efficiency of the proposed system by comparing the existing air source heat pump with ground source heat pump systems, a performance analysis was conducted by setting regional and system configurations as case conditions. The results demonstrate that the electricity use of the MMHP system was 13–19% and 1–3% lower than those of air source heat pump (ASHP) and ground source (GSHP) systems, respectively. In addition, the MMHP system was the most favorable in regions with a low heating load.

Key concepts: Heat pump, Air source heat pumps, Coefficient of performance, Hybrid heat, HVAC, Renewable heat, Environmental science, Electricity

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Performance of Multiple Sources and Multiple Uses Heat Pump System in Three Different Cities — Research Paper | ScholarLens