2020PubMedOpen access

Reliability of Postoperative Radiographies in Ankle Fractures.

Mohammadreza Abbasian, Farsad Biglari, Mehrdad Sadighi, Adel Ebrahimpour

Open full text 7 citations

Abstract

BACKGROUND: The accuracy of reduction of ankle fractures using postoperative plain radiographies (x-ray) remains widely controversial. Some authors have demonstrated that postoperative computed tomography (CT) scan can be useful for these patients. In current study, the efficacy of x-rays after fixation of ankle fractures was investigated based on the CT scan findings. METHODS: A total of 73 patients with ankle fractures who were subjected to open reduction internal fixation (ORIF) were enrolled. After surgery, if the reduction was acceptable based on the x-rays according to standard measurements, the patient was referred for CT scanning. Forty four patients were included in the study. Undesirable CT scan findings including malreduction of fragments or articular surfaces, device malpositioning, missed fractures, and undetected intra-articular fragments were documented. RESULTS: Undesirable CT findings were seen in 25 patients (56.8%). CT scan showed acceptable reduction without device malpositioning in 19 patients. The most prevalent findings in CT images were malreduction and device malpositioning in 17 and 16 patients, respectively. There was no abnormal finding in CT imaging of lateral malleolar fractures. In two thirds of the injured syndesmosis, device malpositioning, and malreduction were detected in CT scan. CONCLUSION: Despite acceptable postoperative x-rays, a considerable number of patients with ankle fractures had inappropriate reduction or undesirable findings in their postoperative CT scan. It seems necessary to use CT scan after ORIF of ankle fractures in order to examine the accuracy of reduction. Further validation of postoperative CT scan in ankle fracture surgery should be investigated.

About this research paper

What this paper is about

BACKGROUND: The accuracy of reduction of ankle fractures using postoperative plain radiographies (x-ray) remains widely controversial. Some authors have demonstrated that postoperative computed tomography (CT) scan can be useful for these patients. In current study, the efficacy of x-rays after fixation of ankle fractures was investigated based on the CT scan findings. METHODS: A total of 73 patients with ankle fractures who were subjected to open reduction internal fixation (ORIF) were enrolled. After surgery, if the reduction was acceptable based on the x-rays according to standard measurements, the patient was referred for CT scanning. Forty four patients were included in the study. Undesirable CT scan findings including malreduction of fragments or articular surfaces, device malpositioning, missed fractures, and undetected intra-articular fragments were documented. RESULTS: Undesirable CT findings were seen in 25 patients (56.8%). CT scan showed acceptable reduction without device malpositioning in 19 patients. The most prevalent findings in CT images were malreduction and device malpositioning in 17 and 16 patients, respectively. There was no abnormal finding in CT imaging of lateral malleolar fractures. In two thirds of the injured syndesmosis, device malpositioning, and malreduction were detected in CT scan. CONCLUSION: Despite acceptable postoperative x-rays, a considerable number of patients with ankle fractures had inappropriate reduction or undesirable findings in their postoperative CT scan. It seems necessary to use CT scan after ORIF of ankle fractures in order to examine the accuracy of reduction. Further validation of postoperative CT scan in ankle fracture surgery should be investigated.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The accuracy of reduction of ankle fractures using postoperative plain radiographies (x-ray) remains widely controversial. Some authors have demonstrated that postoperative computed tomography (CT) scan can be useful for these patients. In current study, the efficacy of x-rays after fixation of ankle fractures was investigated based on the CT scan findings. METHODS: A total of 73 patients with ankle fractures who were subjected to open reduction internal fixation (ORIF) were enrolled. After surgery, if the reduction was acceptable based on the x-rays according to standard measurements, the patient was referred for CT scanning. Forty four patients were included in the study. Undesirable CT scan findings including malreduction of fragments or articular surfaces, device malpositioning, missed fractures, and undetected intra-articular fragments were documented. RESULTS: Undesirable CT findings were seen in 25 patients (56.8%). CT scan showed acceptable reduction without device malpositioning in 19 patients. The most prevalent findings in CT images were malreduction and device malpositioning in 17 and 16 patients, respectively. There was no abnormal finding in CT imaging of lateral malleolar fractures. In two thirds of the injured syndesmosis, device malpositioning, and malreduction were detected in CT scan. CONCLUSION: Despite acceptable postoperative x-rays, a considerable number of patients with ankle fractures had inappropriate reduction or undesirable findings in their postoperative CT scan. It seems necessary to use CT scan after ORIF of ankle fractures in order to examine the accuracy of reduction. Further validation of postoperative CT scan in ankle fracture surgery should be investigated.

Key concepts: Medicine, Ankle, Syndesmosis, Reduction (mathematics), Internal fixation, Surgery, Computed tomography, Fixation (population genetics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Reliability of Postoperative Radiographies in Ankle Fractures. — Research Paper | ScholarLens