2017Brno University of Technology Digital Library (Brno University of Technology)Requires access

Determination of hydroxyproline using ion-exchange liquid chromatography with VIS detector and high performance liquid chromatography with fluorescence detector

Zuzana Lacková, Natalia Cernei, Dagmar Štěrbová, Yazan Haddad, Veronika Rozíková, Tomáš Komprda, Ondřej Zítka

Open publisher page 0 citations

Abstract

The first aim of the experiment was an optimization of the method for determination of hydroxyproline in a pig skin using high-performance liquid chromatography with fluorescence detector (HPLC-FLD) and ion-exchange liquid chromatography with VIS detector (IEC-VIS). On the basis of the experiments performed, it was found that HPLC-FLD method is three times more sensitive than IEC-VIS method. For IEC analysis of hydroxyproline, the limit of detection (LOD) was 4.10 g/ml whereas the limit of quantification (LOQ) was 13.50 g/ml. For HPLC analysis of hydroxyproline, the limit of detection (LOD) was 1 ng/ml whereas the limit of quantification (LOQ) was 3 ng/ml. The second aim was the testing of influence of different volume of 6M HCl on extraction of sample (50 mg) for analysis using HPLC-FLD. Here it was found that the best volume was 250 µl 6M HCl.

About this research paper

What this paper is about

The first aim of the experiment was an optimization of the method for determination of hydroxyproline in a pig skin using high-performance liquid chromatography with fluorescence detector (HPLC-FLD) and ion-exchange liquid chromatography with VIS detector (IEC-VIS). On the basis of the experiments performed, it was found that HPLC-FLD method is three times more sensitive than IEC-VIS method. For IEC analysis of hydroxyproline, the limit of detection (LOD) was 4.10 g/ml whereas the limit of quantification (LOQ) was 13.50 g/ml. For HPLC analysis of hydroxyproline, the limit of detection (LOD) was 1 ng/ml whereas the limit of quantification (LOQ) was 3 ng/ml. The second aim was the testing of influence of different volume of 6M HCl on extraction of sample (50 mg) for analysis using HPLC-FLD. Here it was found that the best volume was 250 µl 6M HCl.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The first aim of the experiment was an optimization of the method for determination of hydroxyproline in a pig skin using high-performance liquid chromatography with fluorescence detector (HPLC-FLD) and ion-exchange liquid chromatography with VIS detector (IEC-VIS). On the basis of the experiments performed, it was found that HPLC-FLD method is three times more sensitive than IEC-VIS method. For IEC analysis of hydroxyproline, the limit of detection (LOD) was 4.10 g/ml whereas the limit of quantification (LOQ) was 13.50 g/ml. For HPLC analysis of hydroxyproline, the limit of detection (LOD) was 1 ng/ml whereas the limit of quantification (LOQ) was 3 ng/ml. The second aim was the testing of influence of different volume of 6M HCl on extraction of sample (50 mg) for analysis using HPLC-FLD. Here it was found that the best volume was 250 µl 6M HCl.

Key concepts: Chromatography, Detection limit, High-performance liquid chromatography, Chemistry, Extraction (chemistry), Hydroxyproline, Ion chromatography, Fluorescence

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of hydroxyproline using ion-exchange liquid chromatography with VIS detector and high performance liquid chromatography with fluorescence detector — Research Paper | ScholarLens